3
S2 CONFIGURATION
(Source Group 1-32 and
Output Address 56 shown)
9
ON [UP]
OFF [DOWN]
1
2
3
4
5
6
7
8
S2 CONFIGURATION
SOURCE GROUP SELECT
The SBX-32 is capable of addressing any of four groups of 32 sources in an ADX matrix system.
To identify which group of 32 sources is being accessed, S2,1 and S2,2 must be set as shown in
the table below.
OUTPUT ADDRESS
The SBX-32 is used to control one (1) output in an ADX matrix system. S2 switches 3 through 9
are used to configure which specific output an individual SBX-32 will control. The SBX-32
OUTPUT ADDRESS table below specifies the switch setting necessary to communicate to the
SCI-ADX which output is to be controlled.
SOURCE GROUP
S2,1
S2,2
1 - 32
OFF
OFF
32 - 64
OFF
ON
65 - 96
ON
OFF
97 - 128
ON
ON
SBX-32 OUTPUT ADDRESS
OUTPUT
S2,3
S2,4
S2,5
S2,6
S2,7
S2,8
S2,9
1
OFF
OFF
OFF
OFF
OFF
OFF
ON
2
OFF
OFF
OFF
OFF
OFF
ON
OFF
3
OFF
OFF
OFF
OFF
OFF
ON
ON
4
OFF
OFF
OFF
OFF
ON
OFF
OFF
5
OFF
OFF
OFF
OFF
ON
OFF
ON
6
OFF
OFF
OFF
OFF
ON
ON
OFF
7
OFF
OFF
OFF
OFF
ON
ON
ON
8
OFF
OFF
OFF
ON
OFF
OFF
OFF
9
OFF
OFF
OFF
ON
OFF
OFF
ON
10
OFF
OFF
OFF
ON
OFF
ON
OFF
11
OFF
OFF
OFF
ON
OFF
ON
ON
12
OFF
OFF
OFF
ON
ON
OFF
OFF
13
OFF
OFF
OFF
ON
ON
OFF
ON
14
OFF
OFF
OFF
ON
ON
ON
OFF
15
OFF
OFF
OFF
ON
ON
ON
ON
16
OFF
OFF
ON
OFF
OFF
OFF
OFF
17
OFF
OFF
ON
OFF
OFF
OFF
ON
18
OFF
OFF
ON
OFF
OFF
ON
OFF
19
OFF
OFF
ON
OFF
OFF
ON
ON
20
OFF
OFF
ON
OFF
ON
OFF
OFF
NOTE: Before any changes in the switch settings take effect, the panel must be reset by removing and restoring power.