TECHNICAL DATA

 

- Function mode: 

pneumatic 

- Air pressure: 

6 bar 

- Air consumption at 6 bar: 

0,04 Nl/double stroke 

- Stroke: 

10 mm 

- Cushioning: 

absorber ring 

- Sensing on cylinder: 

none 

- Ambient temperature: 

- 20 

C ... + 70 

 

MAINTENANCE 

No.  Description 

Interval

2

  Maintenance 

Stopping Unit 

Cleaning  

Stopping Unit 

Inspection of functions and for damages 

H: Hour S: Shift W: Week M: Month J: Year 

WEAR-PARTS / REPLACEMENT-PARTS 

No.  Description 

Stopper bolt 

 

 

 

                                                                 

2

 Depending on cleanliness and usage 

 

Malfunction 

 

Troubleshooting 

-  Pallet doesn’t get stopped 

-  Check position and function of the proximity 

sensors for pallet transfer. 

-  Check the cylinder for mechanical damages. 

-  Check air supply (air tubes,…). 

Summary of Contents for RODOTEC EG

Page 1: ...10 nderungen vorbehalten 1 ANHALTEMODUL VON UNTEN FUNKTION Mit dem Anhaltemodul k nnen die Werkst cktr ger auf der Transportkette an einer beliebigen Stelle angehalten werden Dazu wird mit einem Kurzh...

Page 2: ...g Endlagen berwachung keine Umgebungstemperatur 20 C 70 C WARTUNG Nr Beschreibung Intervall1 Wartung 1 Anhaltemodul M Reinigen 2 Anhaltemodul M Kontrolle der Funktionen und f r Besch digungen H Stunde...

Page 3: ...eb www sigma ch 2019 10 nderungen vorbehalten 3 EINSTELLUNGEN DES KUNSTSTOFFANSCHLAGES Damit das Anhaltemodul allen WT Typen gerecht wird muss der Kunststoff Anschlag eingestellt werden Achtung Einste...

Page 4: ..._U_de en docx Tel 41 41 618 33 44 E Mail info sigma ch Web www sigma ch 2019 10 nderungen vorbehalten 4 BOLZEN IN DIE BEN TIGTE POSITION DREHEN BOLZEN WIEDER IN EINGEFAHRENE POSITION BRINGEN 30 60 WT...

Page 5: ...Rodotec AG M hebachstrasse 5 CH 6370 Stans Datenblatt AHM_U_de en docx Tel 41 41 618 33 44 E Mail info sigma ch Web www sigma ch 2019 10 nderungen vorbehalten 5 PNEUMATISCHE STEUERUNG...

Page 6: ...Web www sigma ch 2019 10 nderungen vorbehalten 6 STOPPING UNIT FUNCTION With the sop module the pallet can be stopped anywhere on the conveyor chain To stop the pallet a short stroke cylinder extends...

Page 7: ...on cylinder none Ambient temperature 20 C 70 C MAINTENANCE No Description Interval2 Maintenance 1 Stopping Unit M Cleaning 2 Stopping Unit M Inspection of functions and for damages H Hour S Shift W W...

Page 8: ...h Web www sigma ch 2019 10 nderungen vorbehalten 8 ADJUSTMENT OF STOPPER BOLT Depending on design of the pallet the plastic stopper must be adjusted two positions are possible Caution Make adjustments...

Page 9: ...blatt AHM_U_de en docx Tel 41 41 618 33 44 E Mail info sigma ch Web www sigma ch 2019 10 nderungen vorbehalten 9 TURN STOPPER TO DESIRED POSITION PRESS STOPPER BACK TO HOME POSITION 30 60 Feeding dire...

Page 10: ...Rodotec AG M hebachstrasse 5 CH 6370 Stans Datenblatt AHM_U_de en docx Tel 41 41 618 33 44 E Mail info sigma ch Web www sigma ch 2019 10 nderungen vorbehalten 10 PNEUMATIC CONTROL...

Reviews: