LOCKOUT: 
User password 
 

 

INPUT IMPEDANCE: 
Voltage 100K current 100 OHMS 
 

 

POWER: 
120/230 VAC 
 

 

ENVIRONMENTAL: 
Operating, 0-65

°

 C 

 

Storage, -40

°

 -80

°

 C 

 

R.H., 0-90% non condensing 

 

 

ENCLOSURE: 
¼ DIN, ABS plastic 96 X 96 X 150MM 
 

 

FRONT PANEL: 
Gasketed Nema 4X 
 

 

ACCESS: 
Chassis & boards remove from front of case. 
 

 

TERMINAL STRIP: 
(20) ‘Pluggable’ for ease of wiring 28 – 16 AWG 
 

 

CONNECTIONS: 
Removable screw terminal blocks 28 – 16 AWG wire. 
 

 

ALARM ANNUNCIATION: 
Multiple alarm annunciation on graphic screen, on board piezo buzzer. 
 

 

PROGRAMMING: 
Menu based, all parameters are user configurable via menu prompts and user keys. The 
preconfigured screens and ‘pull down’ sub menus with English prompts assures rapid setup and 
commissioning.  
 

 

1 YEAR WARRANTY 

 

 

OPTIONS: 
Include relay output, real time clock, expansion cards. 
 

 

M.V. NET: 
Network allows multiple units to be connected together for distributed applications. 
 

 

EXPANSION CARDS: 
Allow up to 8 relay outputs, 8 digital outputs, 8 analog inputs and 8 analog outputs in a single ¼ 
DIN panel mountable case. 

Summary of Contents for Myriad ROS

Page 1: ...MYRIAD ROS REMOTE OPERATOR STATION INSTRUCTION MANUAL MYRIAD ROS MANUAL 062514 VISIT OUR WEBSITE AT SIGMACONTROLS COM...

Page 2: ...cifications Features WIRING 6 7 Dwg 02 111 Dwg 02 119 Dwg 02 120 Analog Input Analog Output Digital Input Digital Output PROGRAMMING AND INITIAL SETUP 8 Input Range Selection Terminal Block Detail Ini...

Page 3: ...ain English menus and combinations of the 5 user data key push buttons Available in 2 styles of mounting DIN 4 x 4 nominal and wall mounted Nema 4X enclosures the Myriad ROS is suitable for installati...

Page 4: ...ALARM ANNUNCIATION Multiple alarm annunciation on graphic screen on board piezo buzzer PROGRAMMING Menu based all parameters are user configurable via menu prompts and user keys The preconfigured scr...

Page 5: ...n Keys 10 Point Linearization Isolated 24VDC Sensor Power 4 20MA 1 5V 0 5V 0 10VDC Input 1 Analog Input 1 Analog Output 2 Digital Outputs Fully User Programmable in English MV Net Port RS 485 User Por...

Page 6: ...6...

Page 7: ...7...

Page 8: ...he main display from any other screen scroll to EXIT and press ENTER ANALOG OUTPUT CONTROL Press the key to increase and the to decrease the analog output value This value is displayed on the main dis...

Page 9: ...en Decimal Point Selector Screen The cursor will be positioned over the decimal count window use the Up Down arrow buttons to raise or lower the unit number to the left of the decimal point The exampl...

Page 10: ...l to SAVE press ENTER to access INPUT SCALE 2 screen Follow the steps outlined above to set the values of input and display for input Scale 2 NOTE IF THE APPLICATION IS A LINEAR ONE BETWEEN THE INPUT...

Page 11: ...the analog output Both the output value and the display value for that output can be selected When complete select NEXT and press ENTER This will bring up the scaling window for analog output Point 2...

Page 12: ...sword Scroll to EXIT to return to the main screen CAUTION ENSURE THAT A RECORD IS KEPT OF THE PROGRAMMED PASSWORD ACCESS IS RESTRICTED TO ALL PROGRAMMABLE PARAMETERS WITHOUT THE CORRECT PASSWORD MENU...

Page 13: ...ut value which will turn the digital OUTPUT 1 off NOTE The internal HORN will sound when the output setpoint is reached To prevent the horn from sounding highlight the Y symbol adjacent to the horn sy...

Page 14: ...it of its liability shall not exceed the purchase price of the supplied equipment RETURN FOR REPAIR POLICY WARRANTY NON WARRANTY REPAIR Return status can be determined upon factory inspection of retur...

Reviews: