background image

F

IGURE 

D

IMENSION 

D

IAGRAM 

FOR 

V

ERTICAL 

U

NIT 

H

EATER 

 

 

 

 

 

 

T

ABLE 

V

ERTICAL 

U

NIT 

H

EATER 

S

PECIFICATIONS

 

D

IMENSIONS 

(

IN

M

ODEL

 

40-V 

18.5 

10 

2.625 

1.25 

1.5 

3/8-16 UNC 

2.75 

6.125 

1.25 

50-V 

18.5 

10 

2.625 

1.25 

1.5 

3/8-16 UNC 

2.75 

6.125 

1.25 

54-V 

22 

13 

2.625 

1.25 

1.5 

3/8-16 UNC 

2.75 

6.125 

1.5 

67-V 

22 

13 

2.625 

1.25 

1.5 

3/8-16 UNC 

2.75 

6.125 

1.5 

78-V 

26.5 

16 

2.625 

1.25 

1.5 

3/8-16 UNC 

2.75 

7.625 

1.625 

100- V 

26.5 

16 

2.625 

1.25 

1.5 

3/8-16 UNC 

2.75 

7.625 

1.625 

145-V 

30.875 

20 

3.375 

1.5 

3/8-16 UNC 

2.75 

7.625 

210-V 

36.875 

25 

3.375 

1.5 

3/8-16 UNC 

2.75 

7.625 

2.375 

300-V 

44.125 

30 

4.125 

2.5 

1/2-13 UNC 

9.125 

370-V 

44.125 

30 

4.125 

2.5 

1/2-13 UNC 

13.625 

375-V 

44.125 

30 

4.125 

2.5 

1/2-13 UNC 

9.125 

480-V 

44.125 

30 

4.125 

2.5 

1/2-13 UNC 

13.625 

 

D

IMENSIONS 

(

IN

M

AX

. M

TG

. H

T

. (

FT

M

ODEL

 

W

(

LB

)

 

W

ITHOUT 

L

OUVER

 

W

ITH 

L

OUVER

 

40-V 

11.5 

12.25 

1.125 

6.25 

8.875 

49 

12 

16 

50-V 

11.5 

12.25 

1.125 

6.25 

8.875 

50 

17 

22 

54-V 

11.875  14.375 

1.25 

10 

62 

13 

16 

67-V 

11.875  14.375 

1.25 

10 

63 

19 

23 

78-V 

12.25 

16.375 

7.25 

10.625 

85 

14 

17 

100- V 

12.25 

16.375 

7.25 

10.625 

90 

21 

25 

145-V 

2.375 

13.5 

20.375 

1.5 

13.25 

118 

23 

28 

210-V 

15.25 

24.5 

1.25 

8.5 

11.875 

146 

26 

32 

300-V 

15.875 

30.5 

0.75 

9.5 

13.75 

200 

26 

32 

370-V 

1.875 

19.25 

30.5 

0.75 

9.5 

13.75 

265 

28 

34 

375-V 

4.5 

17.375 

30.5 

0.75 

9.5 

13.75 

205 

40 

48 

480-V 

2.5 

19.875 

30.5 

0.75 

9.5 

13.75 

270 

42 

52 

 

Unit Heaters 

Installation & Operation Manual 

6

 

www.sigmaproducts.com  Tel: (905) 453-0446   Fax: (905) 453-0675 

Rev 2 

Rev 2 

Summary of Contents for 30-H

Page 1: ...MANUFACTURERS OF HYDRONIC HEATING PRODUCTS Unit Heaters Installation and Operation Manual www sigmaproducts com Tel 905 453 0446 Fax 905 453 0675 Rev 2...

Page 2: ...y to provide any scaffolding or other apparatus to allow service or periodic maintenance to this equipment INSTALLATION Unit Heaters Installation Operation Manual 1 www sigmaproducts com Tel 905 453 0...

Page 3: ...kept clean and free of foreign substances such as excessive joint materials etc For steam systems it is recommended that the unit be mounted level for proper condensate drainage Swing joints should b...

Page 4: ...s where constant water circulation is used on the pain system A louvered cone air diffuser is available as an optional accessory for vertical unit heaters MAINTENTANCE Motor Lubrication Standard motor...

Page 5: ...an guard motor frame and fan bolts Check the fan for clearance in the panel orifice and free rotation The heater system should be checked once per year by a qualified technician All maintenance and se...

Page 6: ...7 50 15 5 0 50 40 9 18 23 40 H 1 22 13 5 4 75 8 7 50 15 5 1 25 40 10 23 29 47 H 2 27 16 5 5 00 8 5 7 75 16 25 1 25 48 10 23 29 58 H 2 27 16 5 5 00 8 5 9 50 18 0 1 25 48 10 28 35 62 H 2 31 5 19 5 5 62...

Page 7: ...13 625 3 375 V 44 125 30 4 125 2 2 5 1 2 13 UNC 3 9 125 3 480 V 44 125 30 4 125 2 2 5 1 2 13 UNC 3 13 625 3 DIMENSIONS IN MAX MTG HT FT MODEL K L M N P R S WT LB WITHOUT LOUVER WITH LOUVER 40 V 3 11 5...

Page 8: ...FIGURE 4 TYPICAL PIPING CONNECTIONS Unit Heaters Installation Operation Manual 7 www sigmaproducts com Tel 905 453 0446 Fax 905 453 0675 Rev 2...

Reviews: