This equipment has been inspected, tested 

and shipped free of defects. However, it is 

the installer’s responsibility to check for 

loose wires, leaks, or loose fasteners, and 

correct any problem that may be found. 

Inspect the equipment immediately when 

received to determine if there is any damage 

from shipment. First, check for visible 

damage to the unit. Turn the fan by hand to 

determine if any damage has occurred. If 

any damage has been found, the receiver 

should note the damage on the bill of lading 

and immediately file a claim with the 

transport company. 

It is the equipment owner’s responsibility to 

provide any scaffolding or other apparatus to 

allow service or periodic maintenance to this 

equipment. 

 

 

I

NSTALLATION

 

  

 

 

Unit Heaters 

Installation & Operation Manual 

1

 

www.sigmaproducts.com  Tel: (905) 453-0446   Fax: (905) 453-0675 

Warning

: Disconnect all power, steam, 

or water supplies before installing or 

servicing the unit.  Do not depend on a 

thermostat or other switch as sole means 

of disconnecting power. Always 

disconnect power at the main breaker. 

 

Caution:

 Insure that all power sources 

conform to the requirements of the unit 

heater or damage to the unit will result. 

All external wiring and piping must 

conform to the local and national codes. 

Warning:

 Improper installation, 

adjustment, alteration, service, or 

maintenance can cause damage, injury, or 

death. Read this manual thoroughly before 

installing, operating, or servicing. 

Rev 2 

Summary of Contents for 30-H

Page 1: ...MANUFACTURERS OF HYDRONIC HEATING PRODUCTS Unit Heaters Installation and Operation Manual www sigmaproducts com Tel 905 453 0446 Fax 905 453 0675 Rev 2...

Page 2: ...y to provide any scaffolding or other apparatus to allow service or periodic maintenance to this equipment INSTALLATION Unit Heaters Installation Operation Manual 1 www sigmaproducts com Tel 905 453 0...

Page 3: ...kept clean and free of foreign substances such as excessive joint materials etc For steam systems it is recommended that the unit be mounted level for proper condensate drainage Swing joints should b...

Page 4: ...s where constant water circulation is used on the pain system A louvered cone air diffuser is available as an optional accessory for vertical unit heaters MAINTENTANCE Motor Lubrication Standard motor...

Page 5: ...an guard motor frame and fan bolts Check the fan for clearance in the panel orifice and free rotation The heater system should be checked once per year by a qualified technician All maintenance and se...

Page 6: ...7 50 15 5 0 50 40 9 18 23 40 H 1 22 13 5 4 75 8 7 50 15 5 1 25 40 10 23 29 47 H 2 27 16 5 5 00 8 5 7 75 16 25 1 25 48 10 23 29 58 H 2 27 16 5 5 00 8 5 9 50 18 0 1 25 48 10 28 35 62 H 2 31 5 19 5 5 62...

Page 7: ...13 625 3 375 V 44 125 30 4 125 2 2 5 1 2 13 UNC 3 9 125 3 480 V 44 125 30 4 125 2 2 5 1 2 13 UNC 3 13 625 3 DIMENSIONS IN MAX MTG HT FT MODEL K L M N P R S WT LB WITHOUT LOUVER WITH LOUVER 40 V 3 11 5...

Page 8: ...FIGURE 4 TYPICAL PIPING CONNECTIONS Unit Heaters Installation Operation Manual 7 www sigmaproducts com Tel 905 453 0446 Fax 905 453 0675 Rev 2...