Connection Diagram for Balance Charging/Storage/Discharge Mode

CAUTION!

 

Always ensure the battery you are charging meets the 

specifications of this charger and that the charger settings are correct. 
Failure to do so can result in excess heat and product malfunction. 
This can lead to user injury or property damage.

Only operate on a fire resistant surface for both the charger & battery.
Always charge in a well ventilated area.

CAUTION! Always power ON the charger before connecting a battery to it or damage to 
the charger and the battery may result.

1.  Connect the Charger to an appropriate power source (AC or DC but 

NEVER

 both)

2. Make program selections in the charger for battery charging
3. Connect balance adaptor board to the charger balance socket
4. Connect the battery to the charger (connect main charging connectors before  

    

    connecting cell-balancing connectors, where used)
5. Start Battery Charging

Exterior

Performance Parameters

WARNING! Read the ENTIRE 
instruction manual to become 
familiar with the features of the 
product before operating.

WARNING! Never leave the 
charger unattended, exceed 
maximum charge rate, charge 
with non-approved batteries or 
charge batteries in the wrong 
mode. Failure to do so may 
result in excessive heat, fire, 
explosions and injury.

AC Input Voltage ...................................................................................................... 100

~

240V

DC Input Voltage ............................................................................................................ 11

~

18V

Charge Current ........................................................................................................... 0.1

~

10A

Discharge Current .....................................................................................................0.1

~

2.0A

Charge Power ....................................................................................................................80W
Discharge Power ............................................................................................................... 10W
Balance Current ............................................................................................................ 350mA
Balance Tolerance.........................................................................................................±0.01V
Charging Capability NiMH/NiCd...............................................................................1

~

16 Cells

Charging Capability LiPo/LiFe/LiIon .........................................................................1

~

6 Series

Pb Battery Voltage ...........................................................................................................2

~

20V

Discharge LiPo/LiFe/LiIon...................................................................................2.0

~

4.2V/Cell

Weight ...............................................................................................................................591g
Dimensions..................................................................................................140 x 180 x 56mm

Sigma EQ Touch II Charger as viewed from the left hand side

Balance Connector sockets: 
High performance 
integrated LiXX balancer 
for 2S to 6S packs using a 
suitable balance board 
and leads, if not XH

Output sockets: Connect the 
battery to be charged using 
the supplied charge lead 
connected to the 4.0mm 
sockets. 

CAUTION! Ensure correct 
polarity!

Temperature Probe Socket

USB Update Socket

Servo 
Test Socket 
(- + Signal)

DC Input
11

~

18V

AC Input
100

~

240V

Cooling 
Fan

USB
Output 5V

Touch Screen

Cooling 
Air Inlet

Summary of Contents for Touch II

Page 1: ...1 10 0A 0 1 2 0A Please read this operating manual completely and carefully as it contains a wide variety of specific programming and safety information The selection of the correct operating paramet...

Page 2: ...uction manual to become familiar with the features of the product before operating WARNING Never leave the charger unattended exceed maximum charge rate charge with non approved batteries or charge ba...

Page 3: ...djust overall parameters and customise 8 Enter into the battery s checking mode For Lithium batteries with balance connector only 9 Enter into the external function mode For Servo testing and USB outp...

Page 4: ...selection correct 2 Number of cells Automatic for BCHG Take care when selecting cell count 3 Charge Discharge Current 4 Save the above settings to a memory 5 Input Voltage Battery Check if not OK chec...

Page 5: ...5V 00 01 4 1 BACK 1 Charging Discharging Data Displays Status 2 Charge Discharge Set Data Continued 3 Graph of total Charge Discharge progress 4 Individual Cell Voltage Lithium batteries with balance...

Page 6: ...W Run Time 00 00 1 3 1 Select USB Monitor or Servo Tester 1 Set Voltage Current Watt Run Time For powering external devices by using charger as a power supply 2 USB Output Monitor 2 Digital Power Wor...

Page 7: ...r the connection has been interrupted Input Voltage Error It is below or over the limit of 11 18V Charger Fault Total Voltage Too Low Total Voltage Too High An individual Cell Voltage is Too Low Warni...

Page 8: ...trical equipment marked with the crossed wheelie bin symbol must not be discarded in the standard household waste Instead it should be taken to a suitable specialist disposal location or your dealer A...