- 7 -
- 8 -
Getting Started Balancing/Charging/Discharging/Cycling
User Set Up
USER SETUP (5/5 )
PB DCHG Cut 1.50V
NiMH DCHG Cut 1.00V
NiCD DCHG Cut 0.80V
LiIo CHG Cut 4.10V
LiIo DCHG Cut 3.10V
BACK
NEXT
:
:
:
:
:
USER SETUP (4/5 )
LiPo CHG Cut 4 .20V
LiPo DCHG Cut 3 .20V
LiFe CHG Cut 3.60V
LiFe DCHG Cut 2.00V
PB CHG Cut 2.40V
BACK
NEXT
:
:
:
:
:
USER SETUP (3/5 )
Nixx Cycle Mode C->D
Nixx Cycle Cnt 2 T
Cycle Wastertime 5Min
NiMH DeltaV 7mv
NiCd DeltaV 10mv
BACK
NEXT
:
:
:
:
:
USER SETUP (2/5 )
Input Cut 10.0V
Safety Timer 240min
Int.Cut-Off 80
℃
Temp.Cut-Off 60
℃
Max Out CAPA 10.1A H
BACK
NEXT
:
:
:
:
:
USER SETUP (1/5)
Back Light 80%
LCD Contrast 40
Button Sound ON
Buzzer Sound ON
Max Out Watt 80W
BACK
NEXT
:
:
:
:
:
Save and Back
INC
DEC
20%-80%
30-60
on/off
on/off
50-80W
1) Battery type -
WARNING!
It is important to get this
selection correct.
2) Number of cells.
(Automatic for BCHG)
Take care when selecting
cell count.
3) Charge/Discharge Current.
4) Save the above settings to
a memory.
5) Input Voltage / Battery Check,
(if not OK, check connections).
10.0-18.0V-
(Cuts operation)
10-600min-
(Total operation time)
50-80-
(Internal temperature)
50-80-
(when using sensor)
500mAh-50Ah-
(Limits total charge capacity)
C->D/D->C
1-5T
5-60Min
5-25mV
5-20mV
4.00-4.25V
3.00-4.00V
3.50-3.70V
1.80-3.30V
2.00-2.50V
1.20-2.00V
0.80-1.50V
0.50-1.50V
4.00-4.15V
3.00-3.90V
M11
M12
M13M
14
M15M
16
M17M
18
OK
BACK
START
LiPo
CHG Confirm
-Connect -
Input Vol ... OK
Mainport ... OK
Bala Port ... OK
TYPE
LiPo
CELLS
6S
CURR
2.2A
Set
Charge Current
2.2 A
SAVE
BACK
STAR T
TYPE
LiPo
CELLS
6S
CURR
2.2A
Number Of Cells
6 (s)
SAVE
BACK
START
TYPE
LiPo
CELLS
6S
CURR
2.2A
Set Battery type
LiPo
SAVE
BACK
START
SET
Display and Sound
Safety and Protection Settings
Custom Settings
Touch The Line To Select
Select From Main Screen
DCHG
CHG
BCHG
CYCLE