background image

- 7 -

- 8 -

Getting Started Balancing/Charging/Discharging/Cycling

User Set Up

USER   SETUP  (5/5 )

PB       DCHG     Cut                  1.50V

NiMH   DCHG    Cut                   1.00V

NiCD   DCHG     Cut                  0.80V

LiIo       CHG        Cut                  4.10V

LiIo       DCHG     Cut                   3.10V

BACK

NEXT

:

:

:

:

:

USER   SETUP  (4/5 )

LiPo  CHG         Cut                     4 .20V

LiPo  DCHG     Cut                     3 .20V

LiFe   CHG        Cut                     3.60V

LiFe   DCHG     Cut                     2.00V

PB    CHG        Cut                     2.40V

BACK

NEXT

:

:

:

:

:

USER   SETUP  (3/5 )

Nixx  Cycle Mode                        C->D

Nixx  Cycle  Cnt                               2 T

Cycle  Wastertime                        5Min

NiMH DeltaV                                 7mv

NiCd  DeltaV                               10mv

BACK

NEXT

:

:

:

:

:

USER   SETUP  (2/5 )

Input Cut                                     10.0V

Safety Timer                             240min

Int.Cut-Off                                     80

Temp.Cut-Off                                 60

Max Out  CAPA                         10.1A H

BACK

NEXT

:

:

:

:

:

USER   SETUP  (1/5)

Back  Light                                  80%

LCD   Contrast                             40

Button  Sound                                ON

Buzzer  Sound                               ON

Max Out Watt                               80W

BACK

NEXT

:

:

:

:

:

Save  and Back

INC

DEC

20%-80%

30-60

on/off

on/off

50-80W

1) Battery type - 

WARNING!

    It is important to get this

    selection correct.

2) Number of cells. 

    (Automatic for BCHG)

    Take care when selecting 

    cell count.

3) Charge/Discharge Current.

4) Save the above settings to

    a memory.

5) Input Voltage / Battery Check, 

    (if not OK, check connections).

10.0-18.0V-

(Cuts operation)

10-600min-

(Total operation time)

50-80-

(Internal temperature)

50-80-

(when using sensor)

500mAh-50Ah-

(Limits total charge capacity)

C->D/D->C

1-5T

5-60Min

5-25mV

5-20mV

4.00-4.25V

3.00-4.00V

3.50-3.70V

1.80-3.30V

2.00-2.50V

1.20-2.00V

0.80-1.50V

0.50-1.50V

4.00-4.15V

3.00-3.90V  

M11

M12

M13M

14

M15M

16

M17M

18

OK

BACK

START

LiPo

  

CHG   Confirm

-Connect -

Input  Vol        ...    OK

Mainport         ...    OK

Bala   Port      ...    OK

TYPE

LiPo

CELLS

    6S

CURR

  2.2A

Set

   

Charge     Current

2.2 A

SAVE

BACK

STAR T

TYPE

LiPo

CELLS

    6S

CURR

  2.2A

Number    Of    Cells

6 (s)

SAVE

BACK

START

TYPE

LiPo

CELLS

    6S

CURR

  2.2A

Set    Battery      type

LiPo

SAVE

BACK

START

SET

Display and Sound

Safety and Protection Settings

Custom Settings

Touch The Line To Select

Select From Main Screen

DCHG

CHG

BCHG

CYCLE

Summary of Contents for Touch II

Page 1: ...1 10 0A 0 1 2 0A Please read this operating manual completely and carefully as it contains a wide variety of specific programming and safety information The selection of the correct operating paramet...

Page 2: ...uction manual to become familiar with the features of the product before operating WARNING Never leave the charger unattended exceed maximum charge rate charge with non approved batteries or charge ba...

Page 3: ...djust overall parameters and customise 8 Enter into the battery s checking mode For Lithium batteries with balance connector only 9 Enter into the external function mode For Servo testing and USB outp...

Page 4: ...selection correct 2 Number of cells Automatic for BCHG Take care when selecting cell count 3 Charge Discharge Current 4 Save the above settings to a memory 5 Input Voltage Battery Check if not OK chec...

Page 5: ...5V 00 01 4 1 BACK 1 Charging Discharging Data Displays Status 2 Charge Discharge Set Data Continued 3 Graph of total Charge Discharge progress 4 Individual Cell Voltage Lithium batteries with balance...

Page 6: ...W Run Time 00 00 1 3 1 Select USB Monitor or Servo Tester 1 Set Voltage Current Watt Run Time For powering external devices by using charger as a power supply 2 USB Output Monitor 2 Digital Power Wor...

Page 7: ...r the connection has been interrupted Input Voltage Error It is below or over the limit of 11 18V Charger Fault Total Voltage Too Low Total Voltage Too High An individual Cell Voltage is Too Low Warni...

Page 8: ...trical equipment marked with the crossed wheelie bin symbol must not be discarded in the standard household waste Instead it should be taken to a suitable specialist disposal location or your dealer A...