SIGLENT
66 SSG5000X Programming Guide
3.6.8.5
Pulse Mode ([:SOURce]:PULM:MODE)
Command
Format
[:SOURce]:PULM:MODE
SINGle|DOUBle|PTRain
[:SOURce]:PULM:MODE
?
Instruction
Set the mode of the pulse generator
Get the mode of the pulse generator
Parameter
Type
Enumeration
Parameter
Range
SINGle|DOUBle|PTRain
SINGle
Enables single pulse generation.
DOUBle
Enables double pulse generation. The two pulses are generated in one
pulse period.
PTRain
A user-defined pulse train is generated The pulse train is defined by value
pairs of on and off times that can be entered in a pulse train list.
Return
Enumeration
Default
SINGle
Menu
PULSE > Pulse Mode
Example
PULM:MODE DOUB
3.6.8.6
Pulse Period ([:SOURce]:PULM:PERiod)
Command
Format
[:SOURce]:PULM:PERiod
<
value
>
[:SOURce]:PULM:PERiod
?
Instruction
Set the period of the generated pulse. The period determines the repetition
frequency of the internal signal
Get the period of the generated pulse
Parameter
Type
Float, unit: ns, us, ms, s
Parameter
Range
40 ns ~ 300 s
Return
Float, unit: s
Default
10 ms
Menu
PULSE > Pulse Period