SIGLENT
104 SSG5000X Programming Guide
Parameter
Range
None
Return
None
Default
None
Menu
ARB > Multi Carrier > Carrier Table > Save
Example
:RADio:DMODulation:ARB:SETup:MCARrier:STORe “test.ml”
3.8.3.5
Waveform Name
([:SOURce]:RADio:DMODulation:ARB:SETup:MCARrier:NAME)
Command
Format
[:SOURce]:RADio:DMODulation:ARB:SETup:MCARrier:NAME
“<waveform>”
[:SOURce]:RADio:DMODulation:ARB:SETup:MCARrier:NAME?
Instruction
This command sets the output waveform name
Parameter
Type
String
Parameter
Range
None
Return
String
Default
MULTICARRIER
Menu
ARB > Multi Carrier > Waveform Name
Example
:RADio:DMODulation:ARB:SETup:MCARrier:NAME “TEST”
3.8.4
[:SOURce]:RADio:ARB Subsystem
3.8.4.1
ARB State ([:SOURce]:RADio:ARB[:STATe])
Command
Format
[:SOURce]:RADio:ARB[:STATe] ON|OFF|1|0
Instruction
This command enables or disables the arbitrary waveform generator
function
Parameter
Type
Boolean
Parameter ON|OFF|1|0