background image

To maximize the distance of transmission, the ideal condition is Line-of-sight (LOS) between the Sigfox sensor and

Base station. In real life, there may be no LOS condition. However, the Sigfox sensor still communicate with Base

station, but the distance will be reduced significantly.

 

7.1 Locate the good place for Radio signal

ATTENTION:

DO NOT

 install the Sigfox sensor or its antenna inside a completed metallic box or housing, because RF signal

can not pass through metallic wall. The housing is made from Non-metallic materials like plastic, glass, wood,

leather, concrete, cement…is acceptable.

7.2 Process mounting

WARNING:

The sensor should be mounted on an oil-free and grease-free surface as close to the source of

vibration as possible.

For best results, the sensor should be mounted via a drill hole and have an 

M6x1.0 threaded hole

(an adapter can be used) attached directly to the housing.

Please make sure that the operating ambient temperature is within the specification of sensor.

Prepare the professional tools for installation. The inappropriate tools may cause damage to the

sensor.

DANGER: Do not twist the upper part of sensor, only screwing the sensor by using the HEX wrench with the

lower HEX part of sensor. 

Summary of Contents for WSSFC-V1A-8-01

Page 1: ...10KHZ VIBRATION SENSOR 25G INTERNAL ANTENNA TYPE AA BATTERY 1 5VDC IP67 RC1 RC6 RC7 ZONES STEP 1 Select RC 1 Select RC zoneusing Modbus Configuration Cable RC zones selection 1 2 4 is RCZ1 RCZ2 RCZ4 r...

Page 2: ...equency response up to 10kHz Its accelerometer feature a stable piezo ceramic crystal in shear mode with low power electronics sealed in a fully hermetic package The Piezo Electric technology incorpor...

Page 3: ...e typical at 24 C 80Hz Connector M12 M 4 pin Coding A Extended cable optional 2m cable with M12 F and M12 M at two ends SIGFOX SPECIFICATION Sigfox zones select RC2 RC3 RC4 RC5 or RC1 RC6 RC7 Antenna...

Page 4: ...times of alarm did not pass the limit of number of alarms then it will send data to Base station immediately 2 When the sending time interval is reached it will send data to Base station immediately r...

Page 5: ...RC4 BLUE colour NOTE Once sending the data to base station by the magnet key the timer of sending time interval will be reset The shortest time interval between the two manual triggers is 15s if shor...

Page 6: ...hen release to configure it Press to configure After pressing if theBlue LED blinks once it is Radio Configuration 1 After pressing if the Blue LED flashes twice it is Radio Configuration 2 After pres...

Page 7: ...y Frequency hopping The device broadcasts each message 3 times on 3 different frequencies Maximum On time 400 ms per channel No new emission before 20 s Listen Before Talk Devices must verify that the...

Page 8: ...Step 3 Click New Select a group Step 4 Fill in the required information...

Page 9: ...ext as shown below Check the box as shown below to register as a prototype Note Some of our products may not have end product certification in time to add the product to Backend Sigfox please follow t...

Page 10: ...ent Peak Peak um Displacement RMS um Base vibration frequency Hz Temperature oC Because the Payload of Sigfox sensor is limited by 12 bytes we use the first 02 bytes for Sensor information and status...

Page 11: ...ttery level 3 60 01 battery level 2 30 00 battery level 1 10 Status error 2 bits Bit 5 and 4 Node status 01 error 00 no error Datagram 4 bits Bit 3 to 0 Datagram 000 Datagram 1 001 Datagram 2 010 Data...

Page 12: ...datagram 3 bit 2 0 disable datagram 3 Some examples of Enb_datagram Enb_datagram 0x0000 Only datagram 1 will be sent Enb_datagram 0x07 0b00000111 Enable 3 datagrams At 1st cycle_send_data Sigfox V1A w...

Page 13: ...wl id qK0PGNbY1g1fuxTqbFW9SXtEvCw7bpc6 Step 2 Plug the configuration cable to Computer via USB port Step 3 Open the housing Serial port configuration on computer 9600 baud None parity 1 stop bit Readi...

Page 14: ...t Step 5 Import the configuration file by importing the csv file Go to MENU FILE Import New select the file with name CONFIGURATION TEMPLATE FILE FOR SIGFOX csv in the link below Then click Connect CO...

Page 15: ...Input Type 15 F 3 1 batt level 0 3 uint16 Read Battery level 16 10 3 1 err_status 0 1 uint16 Read Sensor error code 23 17 3 1 batt 10 30 60 99 uint16 Read Battery 24 18 3 2 batt volt 0 3 67 vdc float...

Page 16: ...k 0 disable Downlink Fw v1 0 hasn t got Downlink function 274 112 3 16 2 cycle_send_data 900 uint32 Read Write Data sending cycle in seconds 278 116 3 16 1 alarm_limit 44 uint16 Read Write Limit numbe...

Page 17: ...metallic materials like plastic glass wood leather concrete cement is acceptable 7 2 Process mounting WARNING The sensor should be mounted on an oil free and grease free surface as close to the source...

Page 18: ...Steps for battery installation Step 1 Using L hex key to unscrew M4 screws at the side of the housing and carefully pull out the top plastic housing in the vertical direction 7 3 Battery installation...

Page 19: ...ry Step 3 Insert the top plastic housing and locking by L hex key ATTENTION REVERSED POLARITY OF BATTERIES IN 10 SECONDS CAN DAMAGE THE SENSOR CIRCUIT ATTENTION When reinstalling the cover pay attenti...

Page 20: ...or the maximum number of alarms per day 3 Node does not send RF to base station when activated by the magnetic switch LED does not blink Magnetic switch has malfunctioned Or place the Magnet key not r...

Page 21: ...ften loses data Distance between Node and Base station is far or there are many obstructions Connection to Antenna problem Check location of Sigfox node and distance to base station Check the antenna...