PSA Installation Guide
6
PowerSync
Analyzer Installation Guide Copyright © 2007-2012 Sifos Technologies, Inc., All Rights Reserved
Physical and Environmental Specifications
PHYSICAL
PSA-100
Width:
4.2 “
Height:
1.65”
Depth:
9.15” (Including Rear-Panel Connectors)
Weight:
1.4 lbs.
Power:
5V, 700mA Max. (100VAC – 240VAC, 50-60Hz Wall Plug-in Adaptor Supplied)
PSA-1200, PSA2400
Width:
19 “
Height:
5.25” (3 Rack-Unit)
Depth:
12”
Weight:
17.25 lbs. (Fully Populated)
Power:
100VAC – 240VAC, 50-60Hz, 600mA Max.
ENVIRONMENTAL
Operating Temperature:
50°C at 20W Max per Port, linearly de-rated from 30°C at 30W per port (see Graph)
Note:
30W is the heat dissipation rating, not the power loading capability of each PSA
Test Port
.
Storage Temperature:
-20°C to 85°C
Operating Humidity:
5% to 95% RH, Non-Condensing.