PSA Installation Guide
11
PowerSync
Analyzer Installation Guide Copyright © 2007-2012 Sifos Technologies, Inc., All Rights Reserved
In the Port Settings Prompt, select the following parameters:
Bits per second >
9600
Data bits >
8
Parity >
None
Stop bits >
1
Flow Control >
Hardware
With HyperTerminal set up and running as described above, hit the
ENTER
key on the Keyboard. The following
menu will appear:
Type
1
and press
ENTER
. Follow the command prompts to set up the IP address. Pay careful attention in the
following example to see how this is done, particularly the assigned
IP Mask
*
method.
There is approximately a 10-second delay before “
Done”
is displayed, and then the main menu appears again:
Type “3” to Enable the PSA.
Then disconnect the serial port and close the terminal emulation software.
NOTE!
The PSA LAN interface
will not operate
if the serial port to the PSA is open and the command menu is
visible by virtue of pressing the
ENTER
key
.
If you are setting up more than one PSA, as in the case of the
PSA-2400 RackPack
, each PSA chassis must have a
unique IP Address.
PowerSync Analyzer
Firmware Version #.##
MAC Address: 00204A######
IP Address: 192.168.221.105
Mask:
255.255.255.0
Gateway:
192.168.1.1
1.
Set IP Address
2.
Firmware Upgrade (Controller)
3.
Enable PSA
(PSA DISABLED) >
>
1
Use DHCP ? (Y/N)>
N
Enter IP Address (xxx.xxx.xxx.xxx) >
10.10.10.114
Confirm? (Y/N)
y
Enter Number of Mask Bits (01 – 30) >
24
255.255.255.0
Confirm? (Y/N)
y
Enter Gateway Address (xxx.xxx.xxx.xxx) >
10.10.10.1
Confirm? (Y/N)
y
Please Wait... Done