Table 28:
PLIC Interrupt Claim/Complete Register for Hart 0 M-Mode
PLIC Claim/Complete Register (
claim
)
Base Address
0x0C20_0004
[31:0]
Interrupt Claim/
Complete for Hart
0 M-Mode
RW
X
A read of zero indicates that no inter-
rupts are pending. A non-zero read
contains the id of the highest pending
interrupt. A write to this register signals
completion of the interrupt id written.
Chapter 10 Platform-Level Interrupt Controller (PLIC)
SiFive FE310-G000 Manual: v3p2
© SiFive, Inc.