background image

 

SIERRA

 

F

RYERS

 

S

ERVICE

 

 

 

WWW.MVPGROUPCORP.COM 

 

S

E

R

V

IC

E

 

I

NSTALLATION

 

NOTICE 

Installation  must  conform  with  local  codes,  or  in  the  absence  of  local  codes,  with  the 

National  Fuel 

Gas  Code,  ANSI  Z223.1,  Natural  Gas  Installation  Code,  CAN/CGA-B149.1,

  or  the 

Propane 

Installation Code, CAN/CGA-B149.2,

 as applicable. 

 

NOTICE 

These installation procedures must be followed by qualified personnel or warranty will be void. 

Local codes regarding installation vary greatly from one area to another. The National Fire Protection 
Association,  Inc.  states  in  its  NFPA  96  latest  edition  that  local  codes  are  the  “authority  having 
jurisdiction” when it comes to installation requirements for equipment. 

Step 1: Unpack 

IMMEDIATELY INSPECT FOR SHIPPING DAMAGE 

All  containers  should  be  examined  for  damage  before  and  during  unloading.  The  freight  carrier  has 
assumed  responsibility  for  safe  transit  and  delivery.  If  damaged  equipment  is  received,  either 
apparent or concealed, a claim must be made with the delivering carrier. 

Apparent damage or loss must be noted on the freight bill at the time of delivery. The freight bill must 
then  be  signed  by  the  carrier  representative  (Driver).  If  the  bill  is  not signed, the  carrier  may  refuse 
the claim. The carrier can supply the necessary forms. 

A request for inspection must be made to the carrier within 15 days if there is concealed damage or 
loss  that  is  not  apparent  until  after  the  equipment  is  uncrated.  The  carrier  should  arrange  an 
inspection. Be certain to hold all contents plus all packing material. 

 

1.  Uncrate carefully. Report any hidden damage to the freight carrier IMMEDIATELY. 

2.  Do not remove any tags or labels until unit is installed and working properly. 

 

Summary of Contents for SRF-35/40

Page 1: ...SRF 35 40 3 Burner Fryer WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructi...

Page 2: ...ctice that could result in injury product damage or property damage NOTICE This symbol refers to information that needs special attention or must be fully understood even though not dangerous WARNING...

Page 3: ...ou will experience years of reliable trouble free operation For best results read this manual carefully RETAIN THIS MANUAL FOR FUTURE REFERENCE MODELS This manual is for Sierra Fryers with 35 40 lb ca...

Page 4: ...ure should be minimum of 4 W C for natural gas or 10 W C for propane The fryer comes with NPT male connector on a pipe allowing you to connect with either or NPT female connector Model Burners Gas Typ...

Page 5: ...iners should be examined for damage before and during unloading The freight carrier has assumed responsibility for safe transit and delivery If damaged equipment is received either apparent or conceal...

Page 6: ...mum performance Improper leveling may void warranty NOTICE When this appliance is installed with casters it must be installed with the casters supplied a connector complying with either ANSI Z21 69 CS...

Page 7: ...MVPGROUPCORP COM 7 SERVICE Step 3 Flue Installation 1 Unpack the flue box and flue wrap 2 Slide the flue box over the flue and secure it with the two self tapping screws using a 5 16 socket 3 Slide th...

Page 8: ...SIERRA FRYERS SERVICE WWW MVPGROUPCORP COM 8 SERVICE 4 Secure it with four self tapping screws two on the back and one on each side using a 5 16 socket...

Page 9: ...ot obstructed Provisions for adequate air supply must also be provided Do NOT obstruct the bottom front of the unit as combustion air enters through this area Be sure to inspect and clean the ventilat...

Page 10: ...y line when all units are operating simultaneously should not drop below 7 W C for natural gas or 11 W C for propane gas Fluctuations of more than 25 on natural gas or 10 on propane gas will create pr...

Page 11: ...valve turn it counterclockwise to the PILOT position shown and continue to press the knob down 3 While pressing the knob down use a lit match to ignite the pilot Continue to press the knob down for ab...

Page 12: ...around the heat tube surfaces when the heat is turned on the tube surfaces will become red hot burn the solid shortening weaken the frypot and could result in a fire Gradual heating is required for s...

Page 13: ...eans that the temperature is too high or that the oil has broken down Gum in frypot denotes a need for thorough cleaning see Weekly Cleaning on page 14 Use different oil for oily foods fish heavily se...

Page 14: ...o a gentle boil for at least five minutes 4 Turn off main burners and let the solution stand until the gum deposits are softened and the carbon spots and burned grease spots can be rubbed off 5 Scrub...

Page 15: ...he above cleaning techniques but tint which does not respond to that procedure calls for a vigorous scouring in the direction of the polish lines using SCOTCH BRITE brand scouring pads or a STAINLESS...

Page 16: ...steady blue flame and the inner cone of the flame from each port should be about 3 4 long The flame from each main burner should enter each heat tube without touching the front of the frypot or the si...

Page 17: ...pressure tap plug 11 Replace adjustment screw cap CHECKING AND ADJUSTING CALIBRATION OF THERMOSTAT All thermostat controls are carefully calibrated at the factory i e the dial is properly set to contr...

Page 18: ...on Gas supply to unit off Combination gas valve is in OFF or PILOT position Pilot not ignited Thermostat not ON Inadequate gas pressure Pilot will not stay ignited Combination gas valve is in OFF posi...

Page 19: ...or shock caused by shaking or pounding baskets on top surface or by slamming door may cause Hi Limit Control Switch to open If this condition persists additional cushioning may be added to the rubber...

Page 20: ...e the front door on the left side Replacement parts may be ordered either through a SIERRA Authorized Parts Distributor or a SIERRA Authorized Service Agency When ordering parts please supply the Mode...

Page 21: ...ensys 4 119 0009 1 Combination valve LP _Invensys 4 Call 1 Combination Valve Nat _Honeywell 4 Call 1 Combination valve LP _Honeywell 5 119 0016 1 Tubing fryer pilot 10 119 0007 ea Burner Fryer 11 119...

Page 22: ...PCORP COM 22 Tank Parts Key Part Number Qty Description 1 119 0003 1 Screen crumb 2 119 0017 1 Valve Ball 3 call 1 Tank excluding flue 4 119 0018 1 Drain extension 5 call 1 Flue top removable 6 call 1...

Page 23: ...ounting hardware 4 119 0021 Caster Kit 4 adjustable set of 4 two w brake and two w o brake 5 119 0001 Magnet door 6 119 0002 Basket double CONTACT INFORMATION MVP GROUP CORPORATION 5659 Royalmount Ave...

Page 24: ...all be limited to regular hourly rates only Any supplemental hourly rates or charges such as weekends or emergency premiums remain the responsibility of the user MVP Group Corporation Sierra hereby st...

Page 25: ...ecessary to extend the useful life of this unit When service is needed contact a SIERRA Authorized Service Agency or your dealer To avoid confusion always refer to the model number serial number and t...

Reviews: