S
IERRA
F
RYERS
S
PECIFICATIONS
WWW.MVPGROUPCORP.COM
4
S
P
E
C
IF
IC
A
TIO
N
S
S
PECIFICATIONS
DIMENSIONS
Note: for mm, multiply inches by 25.4
Model
Width (in)
Depth (in)
Height (in)
Gas Connection (in)
Total
BTU/hr.
Crated
Weight
(lbs)
A
B
C
D
E
F
G
H
I
SRF-35/40
15.5
14.0
30.3
14.0
47.2
36.2
6.0
4.2
8.0
90,000
150
GAS SUPPLY AND BURNER INFORMATION
Supply pressure should be minimum of 4" W.C. for natural gas or 10" W.C. for propane.
The fryer comes with ¾”
NPT male connector on a ½” pipe, allowing you to connect with either ¾” or ½” NPT female connector.
Model
Burners
Gas Type
Manifold
Pressure
Number of
heat tube
Rate Each
BTUs / Hour
Total Rate
BTUs / Hour
Orifice Size
SRF-35/40
Main
Natural
4" W.C.
3
30,000
90,000
#39
Propane
10" W.C.
3
30,000
90,000
#52
* Minimum supply pressure is 4" W.C. for natural gas and 10" W.C. for propane.
** Orifice sizes are for units installed at altitudes between 0 and 2000 feet above sea level.