SIERRA
F
RYERS
S
ERVICE
WWW.MVPGROUPCORP.COM
11
S
E
R
V
IC
E
PHOTO 1
O
PERATION
LIGHTING
!
CAUTION
IF YOU SMELL GAS DURING THE LIGHTING PROCEDURE, IMMEDIATELY SHUT OFF THE GAS
SUPPLY UNTIL THE LEAK HAS BEEN CORRECTED.
Open the burner compartment door and do the following:
1.
Turn thermostat to “OFF”
2.
Press down the knob of the combination gas valve, turn it counterclockwise to the “PILOT” position
(shown), and continue to press the knob down.
3. While pressing the knob down, use a lit match to ignite the pilot. Continue to press the knob
down for about 30 seconds. If the pilot does not stay lit when the knob is released, repeat the
lighting procedure and keep the knob down longer. Adjustment of pilot flame may be necessary.
4.
When the pilot stays lit, turn the knob counterclockwise to the “ON” position. Do not press down
on the knob in this step.
Invensys 7000BMVR
Honeywell VS8200