Sierra NS-1N30-00 Manual Download Page 8

8

42445 Avenida Alvarado, Temecula, CA  92590

(800) 451-9343,  www.nimbuswater.com

Determine the most practical under-the-sink location for placement of the Sierra manifold unit and the companion reservoir 

tank.  Ensure that the specific location allows adequate access to the manifold unit for cartridge re placement and to the 

tank for tank- valve operation.

  

1. Place the manifold and tank in the selected locations.  If desired, the #6 self tapping screws may be used to secure the 

manifold unit in position by means of the top rear and bottom lip mounting holes. 

2. Take the unused portion of the 3/8" white tubing and insert one end firmly into the 3/8" (largest) connector on the top of 

the manifold unit.  

3. Extend the 3/8" white tubing from the manifold unit to the tank valve.  Leave enough slack in the tubing to allow the unit 

to be removed from the installed location for servicing.  Cut off the excess and insert the 3/8" tube into the quick-connect 

tank valve fitting until it is fully engaged. 

 

4.  Extend the 1/4" yellow tubing from the faucet unit to the manifold.  Leave enough slack in the tubing to allow the unit to 

be removed from the installed location for servicing.  Cut off the excess and firmly insert the tubing into the corresponding 

yellow drain connection located on the manifold.

5. Extend the 3/8" blue tubing from the faucet unit to the manifold.  Leave enough slack in the tubing to allow the unit to be 

removed from the installed location for servicing.  Cut off the excess and firmly insert the tubing into the corresponding blue 

product water connection located on the manifold. 

6. Extend the green tubing from the feed connector valve to the manifold. Leave enough slack in the tubing to allow the unit 

to be removed from the installed location for servicing. Cut off the excess and firmly insert the tubing into the correspond-

ing green feed connection located on the manifold. 

7. Obtain the Shutoff Warning label and affix it to the manifold unit so that it is directly visible. The Sierra system is now con-

nected and ready for initial test and preparation. 

TUBING HINTS:    Use a sharp knife or tubing cutter to cut the tubing squarely, being sure to remove all burrs.   Then insert the 

tubing firmly until it stops.   To remove the tubing, push against the collet while pulling on the tubing.

 

Manifold Installation

Summary of Contents for NS-1N30-00

Page 1: ...1 42445 Avenida Alvarado Temecula CA 92590 800 451 9343 www nimbuswater com 42445 Avenida Alvarado Temecula CA 92590 800 451 9343 www nimbuswater com REVERSE OSMOSIS DRINKING WATER SYSTEM 0216 ...

Page 2: ... CA 92590 800 451 9343 www nimbuswater com Model Date Code Install Date Sold by Installed By Service Center Phone Number Please fill out the following information at the time of installation Save for future reference Sierra NS 1N30 00 ...

Page 3: ...mon hand and power tools If you are not familiar with standard sink plumbing and proper use of common hand and power tools or have any difficulty with the installation of this system consult a licensed professional such as a contractor or plumber NOTE This system has been designed for installation by licensed professionals such as a contractor or plumber Introduction To The Sierra Stage Descriptio...

Page 4: ...s no liability for the determination of the proper equipment necessary to meet your requirements and we do not authorize others to assume such obligation on our behalf This Limited Warranty does not cover any Manufacturer supplied items that are defective as a result of the use of improper parts equip ment or materials This warranty does not cover alterations or modifications of the unit or failur...

Page 5: ...instructions outline a typical water treatment system installation Consult local plumbing codes and building regulations as they may pose different or additional requirements for the installation The installer is responsible for ensuring that the installation is in compliance with all applicable state and local regulations This system has been designed for installation by a licensed professional s...

Page 6: ...e small adhesive foam pad from the small parts bag Fig 2 3 Place the adhesive foam pad on the inside of the drain saddle front aligning the holes 4 Position the drain saddle on the drain pipe under the sink between the P trap and the sink connection Orient the drain saddle so that the opening is on the side of the drain pipe 5 Using the bolts and hex nuts hand tighten the saddle bracket evenly unt...

Page 7: ...th similar thickness 8 Thread the 3 8 washer 3 serrated washer 4 and mounting lock nut 5 onto the threaded stem 9 Thread faucet quick connect adapter 6 on to threads of faucet stem NOTE This connection should be hand tightened only Push one end of 3 8 blue tubing into 3 8 connection 10 Insert tubing and faucet assembly down through the sink hole 11 Position the faucet to the desired handle orienta...

Page 8: ... Leave enough slack in the tubing to allow the unit to be removed from the installed location for servicing Cut off the excess and firmly insert the tubing into the corresponding yellow drain connection located on the manifold 5 Extend the 3 8 blue tubing from the faucet unit to the manifold Leave enough slack in the tubing to allow the unit to be removed from the installed location for servicing ...

Page 9: ...orinated sanitizer before shipment in order to ensure tank internal cleanliness Also the carbon filter cartridges will release a small amount of carbon fines during the first tankful of flow This flushing procedure will allow any sanitizer or carbon fines to pass from the system 2 Initial tank filling will take approximately two and one half hours based on average feed pressure When the tank is fu...

Page 10: ... Press top or bottom of cartridge to engage connectors until it snaps into place properly 4 All tubing connections especially push in quick connections are fully inserted 5 Tubing connected between the faucet and the drain saddle fitting the fitting attached to the sink drain pipe runs down hill to the drain There should be no loops or places where water would not flow out to the drain 6 Feed wate...

Page 11: ...d in the unit connectors Install the retaining clip ensuring the slide locks snap into place in the slots If the clip does not snap easily into place through the slots it means the cartridge is not fully inserted into the connectors Press the top or bottom of the cartridge to engage the connector so that it snaps fully into place 7 Repeat Steps 5 and 6 for each cartridge to be replaced 8 Turn on f...

Reviews: