Congratulations on your purchase of the Nimbus Sierra reverse osmosis system.  When properly maintained, this system will 

provide you with years of trouble-free service.   The next sections contain important information on proper care and mainte-

nance. Please take a few minutes to read through this information.

The cartridges in this system must be replaced on a regular basis to maintain  efficiency and to ensure high water quality.  

These cartridges work together and must be replaced every  6-12 months.  Any significant change in performance of the 

system should be investigated promptly to avoid secondary damage or deterioration to other parts of the system.

CAUTION: Improperly installed systems could result in water damage due to leaks or flooding.  Proper installation of this 

system requires familiarity with standard sink plumbing and proper use of common hand and power tools.  If you are not 

familiar with standard sink plumbing and proper use of common hand and power tools or have any difficulty with the 

installation of this system, consult a licensed professional, such as a contractor or plumber.  

NOTE:  This system has been designed for installation by licensed professionals, such as a contractor or plumber. 

Introduction To The Sierra

Stage

Description

Cap Color

Replacement 

Interval

1 & 2

20 micron sediment  

prefilter plus granular 

 

activated carbon.

Green

6-12 months

3

Reverse osmosis membrane

White

12 months

or when TDS  

rejection falls 

below 85%

4

Granular activated carbon 

post-filter

Blue

6-12 months

System Performance 

Daily production rate 

 

 

42.8 L/d (11.3 gpd)       

Total Dissolved Solids Reduction  

 

96.4% 

  

Feed Water Requirements

Feed Water  

 

 

Potable, municipal water

Feed Pressure 

 

 

40psi - 80psi

Feed temperature 

 

 

40°F to 100°F

Total dissolved solids  

 

 

2,000 mg/L max 

Chlorine 

 

 

<1.0 mg/L max. 

pH 

 

 

4-8

Turbidity 

 

 

<1.0 NTU

SDI 

 

 

<5

Iron, Manganese, Hydrogen Sulfide   

0 ppm 

  

Do not use with water that is microbiologically unsafe or of unknown quality without adequate  

disinfection before or after the system.

Summary of Contents for NS-1N30-00

Page 1: ...1 42445 Avenida Alvarado Temecula CA 92590 800 451 9343 www nimbuswater com 42445 Avenida Alvarado Temecula CA 92590 800 451 9343 www nimbuswater com REVERSE OSMOSIS DRINKING WATER SYSTEM 0216 ...

Page 2: ... CA 92590 800 451 9343 www nimbuswater com Model Date Code Install Date Sold by Installed By Service Center Phone Number Please fill out the following information at the time of installation Save for future reference Sierra NS 1N30 00 ...

Page 3: ...mon hand and power tools If you are not familiar with standard sink plumbing and proper use of common hand and power tools or have any difficulty with the installation of this system consult a licensed professional such as a contractor or plumber NOTE This system has been designed for installation by licensed professionals such as a contractor or plumber Introduction To The Sierra Stage Descriptio...

Page 4: ...s no liability for the determination of the proper equipment necessary to meet your requirements and we do not authorize others to assume such obligation on our behalf This Limited Warranty does not cover any Manufacturer supplied items that are defective as a result of the use of improper parts equip ment or materials This warranty does not cover alterations or modifications of the unit or failur...

Page 5: ...instructions outline a typical water treatment system installation Consult local plumbing codes and building regulations as they may pose different or additional requirements for the installation The installer is responsible for ensuring that the installation is in compliance with all applicable state and local regulations This system has been designed for installation by a licensed professional s...

Page 6: ...e small adhesive foam pad from the small parts bag Fig 2 3 Place the adhesive foam pad on the inside of the drain saddle front aligning the holes 4 Position the drain saddle on the drain pipe under the sink between the P trap and the sink connection Orient the drain saddle so that the opening is on the side of the drain pipe 5 Using the bolts and hex nuts hand tighten the saddle bracket evenly unt...

Page 7: ...th similar thickness 8 Thread the 3 8 washer 3 serrated washer 4 and mounting lock nut 5 onto the threaded stem 9 Thread faucet quick connect adapter 6 on to threads of faucet stem NOTE This connection should be hand tightened only Push one end of 3 8 blue tubing into 3 8 connection 10 Insert tubing and faucet assembly down through the sink hole 11 Position the faucet to the desired handle orienta...

Page 8: ... Leave enough slack in the tubing to allow the unit to be removed from the installed location for servicing Cut off the excess and firmly insert the tubing into the corresponding yellow drain connection located on the manifold 5 Extend the 3 8 blue tubing from the faucet unit to the manifold Leave enough slack in the tubing to allow the unit to be removed from the installed location for servicing ...

Page 9: ...orinated sanitizer before shipment in order to ensure tank internal cleanliness Also the carbon filter cartridges will release a small amount of carbon fines during the first tankful of flow This flushing procedure will allow any sanitizer or carbon fines to pass from the system 2 Initial tank filling will take approximately two and one half hours based on average feed pressure When the tank is fu...

Page 10: ... Press top or bottom of cartridge to engage connectors until it snaps into place properly 4 All tubing connections especially push in quick connections are fully inserted 5 Tubing connected between the faucet and the drain saddle fitting the fitting attached to the sink drain pipe runs down hill to the drain There should be no loops or places where water would not flow out to the drain 6 Feed wate...

Page 11: ...d in the unit connectors Install the retaining clip ensuring the slide locks snap into place in the slots If the clip does not snap easily into place through the slots it means the cartridge is not fully inserted into the connectors Press the top or bottom of the cartridge to engage the connector so that it snaps fully into place 7 Repeat Steps 5 and 6 for each cartridge to be replaced 8 Turn on f...

Reviews: