background image

6

42445 Avenida Alvarado, Temecula, CA  92590

(800) 451-9343,  www.nimbuswater.com

Feed  and Drain Connections

Feed Connection

1.  Locate and turn off the angle stop valve on the cold water line feeding the sink.  This valve will 

usually be located under the sink on the pipe coming out of the wall. 

 

2.  When the angle stop valve is closed, relieve pressure in the line by momentarily opening the 

cold water tap on the sink. 

3.  Disconnect the cold water faucet feed line at the angle stop valve. 

4.  Install the feed valve assembly into the angle stop. (Fig. 1)

5.  Firmly press the green 1/4” tubing into the 1/4" connector on the feed valve assembly.

6.  Connect the cold water faucet feed line into the feed valve assembly.

7.  Make sure the small shut-off valve on the feed valve assembly is closed.  Turn on the feed water  

connection valve.  Check for leaks.  

7.  Attach the small feed valve warning tag from the parts bag to the feed valve.  

8.  Attach the Shutoff Warning label to the system so that it is directly visible. Fill out the Date of 

Installation label and attach to the side of the system.

Drain Connection

1.  You will need an electric drill with a 3/8” bit and a screwdriver for this portion of the installa-

tion.  

2.  Obtain the drain saddle assembly, two 1 ½” bolts, two 3/8” hex nuts, and the small adhesive 

foam pad from the small parts bag (Fig. 2).

3.  Place the adhesive foam pad on the inside of the drain saddle front, aligning the holes.  

4.  Position the drain saddle on the drain pipe under the sink between the “P” trap and the sink 

connection.  Orient the drain saddle so that the opening is on the side of the drain pipe.  

5.  Using the bolts and hex nuts, hand tighten the saddle bracket evenly until the saddle grips the 

pipe snugly.  Use a Phillips screwdriver to fully tighten the bolts.   Do not overtighten.

6.  If necessary, remove the drain saddle connector nut from the opening of the drain saddle.   

Using the connector opening in  the side of the drain saddle as a guide, drill a 3/8" hole through 

the wall of the drain pipe.  

7.  Extend the drain tubing from the RO dispensing faucet to the drain saddle and measure for 

length.  The tubing must be routed so that water can run downhill for the entire length of the  

tubing from the faucet.  Avoid low spots or loops.  Cut the tubing shorter, if necessary.

8.  Insert the drain tube from the R.O. dispensing faucet through the drain saddle connector nut.  

Tighten the connector nut onto the drain saddle.

Fig. 2

Note: The drain saddle 

assembly must be 

installed before the 'P' 

trap.  Do not install the 

drain saddle assembly 

between the 'P' trap 

and the wall. 

Adapter

Shut-off valve

Fig. 1

Note: The feed valve 

adapter may be  

configured to fit either 

a 3/8" or 1/2" angle 

stop connection by 

changing the location 

of the adapter.

Angle stop

Summary of Contents for NS-1N30-00

Page 1: ...1 42445 Avenida Alvarado Temecula CA 92590 800 451 9343 www nimbuswater com 42445 Avenida Alvarado Temecula CA 92590 800 451 9343 www nimbuswater com REVERSE OSMOSIS DRINKING WATER SYSTEM 0216 ...

Page 2: ... CA 92590 800 451 9343 www nimbuswater com Model Date Code Install Date Sold by Installed By Service Center Phone Number Please fill out the following information at the time of installation Save for future reference Sierra NS 1N30 00 ...

Page 3: ...mon hand and power tools If you are not familiar with standard sink plumbing and proper use of common hand and power tools or have any difficulty with the installation of this system consult a licensed professional such as a contractor or plumber NOTE This system has been designed for installation by licensed professionals such as a contractor or plumber Introduction To The Sierra Stage Descriptio...

Page 4: ...s no liability for the determination of the proper equipment necessary to meet your requirements and we do not authorize others to assume such obligation on our behalf This Limited Warranty does not cover any Manufacturer supplied items that are defective as a result of the use of improper parts equip ment or materials This warranty does not cover alterations or modifications of the unit or failur...

Page 5: ...instructions outline a typical water treatment system installation Consult local plumbing codes and building regulations as they may pose different or additional requirements for the installation The installer is responsible for ensuring that the installation is in compliance with all applicable state and local regulations This system has been designed for installation by a licensed professional s...

Page 6: ...e small adhesive foam pad from the small parts bag Fig 2 3 Place the adhesive foam pad on the inside of the drain saddle front aligning the holes 4 Position the drain saddle on the drain pipe under the sink between the P trap and the sink connection Orient the drain saddle so that the opening is on the side of the drain pipe 5 Using the bolts and hex nuts hand tighten the saddle bracket evenly unt...

Page 7: ...th similar thickness 8 Thread the 3 8 washer 3 serrated washer 4 and mounting lock nut 5 onto the threaded stem 9 Thread faucet quick connect adapter 6 on to threads of faucet stem NOTE This connection should be hand tightened only Push one end of 3 8 blue tubing into 3 8 connection 10 Insert tubing and faucet assembly down through the sink hole 11 Position the faucet to the desired handle orienta...

Page 8: ... Leave enough slack in the tubing to allow the unit to be removed from the installed location for servicing Cut off the excess and firmly insert the tubing into the corresponding yellow drain connection located on the manifold 5 Extend the 3 8 blue tubing from the faucet unit to the manifold Leave enough slack in the tubing to allow the unit to be removed from the installed location for servicing ...

Page 9: ...orinated sanitizer before shipment in order to ensure tank internal cleanliness Also the carbon filter cartridges will release a small amount of carbon fines during the first tankful of flow This flushing procedure will allow any sanitizer or carbon fines to pass from the system 2 Initial tank filling will take approximately two and one half hours based on average feed pressure When the tank is fu...

Page 10: ... Press top or bottom of cartridge to engage connectors until it snaps into place properly 4 All tubing connections especially push in quick connections are fully inserted 5 Tubing connected between the faucet and the drain saddle fitting the fitting attached to the sink drain pipe runs down hill to the drain There should be no loops or places where water would not flow out to the drain 6 Feed wate...

Page 11: ...d in the unit connectors Install the retaining clip ensuring the slide locks snap into place in the slots If the clip does not snap easily into place through the slots it means the cartridge is not fully inserted into the connectors Press the top or bottom of the cartridge to engage the connector so that it snaps fully into place 7 Repeat Steps 5 and 6 for each cartridge to be replaced 8 Turn on f...