background image

4

Figure 7

 

Rear Connection Panel

Figure 8 Stove Connection Panel

Autolite Wiring Diagram

UNIT  INSTALLATION

Route the power supply cord so that it does not touch

any of the exterior com ponents of the he ater.

1.

W hen exiting through the wall with your type L Pellet
vent p ipe, you  m ay go straight ou t throu gh  a wall
thim ble.  You m us t co nn ec t a p ellet vent te e at this
point and  exte nd th e vent pipe  at leas t 

3'

 (three  feet)

vertically outside to provide good draft and allow the
gases to exit. The tee must have a clean out cap for
inspection and regular cleaning (

Figure 4)

. Horizontal

runs must be limited to 

2'

 (two fe et). A w all ban d is

requ ired fo r ev ery 

4'

 (four feet) minimum  on a vertical

run at an  exterior wa ll.

2.

All pellet vent pipe connections including exit at the
rear of the heater should be sealed with high
tem pe rature silicone  (45 0°) or m eta llic duc t tap e. T his
prevents smok e and soot leakage into the living area.
If this is not done, there is a possibility that the room
fan will pick up any leakage and blow it into the room.

AUTOLITE INSTALLATION INSTRUCTIONS

  Th e A uto Lite  Sys tem  is fa cto ry ins talle d w ith th e only
installation  requ irem ents  being  the optiona l therm osta t.

Wall Thermostat Installation:

  Th e wa ll therm osta t is des igned to autom atically reg ulate
the room tem perature from the control panel heat setting
to the “Off” setting based upon room temperature.
Rem ember to leave the control panel on the "Medium or
High" position when utilizing the wall thermostat feature.

  The following is a step by step procedure for installing the
optional wall therm ostat. Note conne ction terminals on left
side of unit at rear (

Fig ure  7,8

). Use 18/2 therm ostat wire

for the installation.

a.

Unplug he ater from  wall outlet and 12V DC  power!

b.

Rem ove factory jump wire and hook up thermostat
wires to terminals (

Fig ure  7,8

).

c.

Locate thermostat approximately 10 to 12 feet from
heater or in area that requires steady temperature.

d.

Run thermostat wires from heater to thermostat
along wa ll or und er ca rpet e tc. an d ho ok  wires  to
thermostat terminals.  On new construction you
can, of course, run wire in the walls before sheet
rock or paneling is done.

e.

Reco nnect AC  power.

f.

Make sure all wiring is completed before plugging
the E AS YFIR E H eate r bac k into  the w all outlet.

IMPORTANT

 - Any electrical work performed on the

EA SY FIRE H ea ter shou ld  be don e by qualifie d perso nn el.

Remote Control Thermostat Installation:

  Th e re m ote  the rm os tat is  desig ne d to  autom atic ally
regulate the room temperature from the control panel heat
setting to the “Off” setting base d upon roo m  temp erature
and  place m ent o f the re m ote therm osta t. Rem em ber to
leave the control panel on the "Medium or High" position
when utilizing the wall thermostat feature.

  The following is a step by step procedure for installing the
optional remote thermostat. Note connection terminals on
rear  of un it (

Fig ure  1,2

).

a.

Unplug he ater from  wall outlet and 12V DC  power!

b.

Mount millivolt style remote receiver box to rear of
stove using double-sided tape.

b.

Rem ove factory jump wire and hook up thermostat
wires to terminals (

Fig ure  7,8

).

d.

Re con nec t AC  pow er an d follow  instructions  with
remote thermostat regarding set up.

IMPORTANT

 - Any electrical work performed on the

 EA SY FIRE H ea ter shou ld  be don e by qualifie d perso nn el.

DOOR HANDLE ASSEMBLY

The door handle and latch must be assembled and adjusted
prior to the operation of the stove.

1.

Position hand le ass em bly throu gh d oor a nd s ecu re with
collar by sliding over shaft and tightening with allen
wrench provided (

Figure 9

).

2.

Position latch on end of shaft with flat facing allen screw.
Depending on gasket, shaft will protrude approx. 1/4"
through back of latch collar. Snug allen screw.

Summary of Contents for EasyFire EF-3801B-AL

Page 1: ...ype L Pellet Vent System NEVER use gasoline gasoline type lantern fuels kerosene charcoal lighter fluid or similar liquids to start or freshen up a fire Keep all such liquids well away from the heater...

Page 2: ...in all residential applications An outside air inlet MUST be provided for combustion and ventilation air The air inlet must remain unrestricted while unit is in use Outside air connection is located...

Page 3: ...3 Figure 3 Figure 4 Figure 5 Figure 6 c 2 ft minimum to an adjacent building and 7 ft minimum above grade when located adjacent to public walkways...

Page 4: ...emove factory jump wire and hook up thermostat wires to terminals Figure 7 8 c Locate thermostat approximately 10 to 12 feet from heater or in area that requires steady temperature d Run thermostat wi...

Page 5: ...deactivated and the stove operates based on the EasyFire digital control system requirements If the house AC power should quit the AutoLite system will not be available however with the optional batte...

Page 6: ...the stove will begin to heat up When the stove reaches start up operating temperature it will then switch to the control panel setting and begin it s automatic operation cycle Feed Trim Adjustment Und...

Page 7: ...spring to return against stop Figure 10 11 Once ash box is full box should be placed in a non combustible floor or on the ground well away from all combustible materials pending final disposal If the...

Page 8: ...equires routine maintenance for maximum performance and is mandatory for the warranty to remain in effect The following procedures should be studied carefully and performed regularly as indicated 1 Fl...

Page 9: ...ist for specifications TROUBLE SHOOTING The following scenarios are provided in order to help you locate a difficulty if the heater performs in a manner which would seem to indicate a malfunction l Pr...

Page 10: ...em when the hopper door is open If fuel is to be added while heater is in operation it must be accomplished with in several minutes of opening the door 9 Problem I turned off the switch and the heater...

Page 11: ...R 4 110451 ASH DUMP KNOB 5 300522 ASH DRAWER 6 200549 HEAT EXCHANGE COVER 7 300500 FIREPOT AL V2 8 120117 AUTOLITE IGNITER 9 202164 BURN POT SCREEN AL 10 120120 AUTOLITE POWER RELAY 11 120118 AUTOLITE...