Figure 15

Figure 16

Figure 17

4.

Clearance to combustibles may only be reduced by
m ea ns  approved  by th e re gu lato ry au tho rity.

5.

Store pellet fuels in a dry area away from unit. Do not
store fuels within the space heater installation
clearances or within the space required for charging
an d ash  rem oval.

6.

Ad eq ua te ven tilatio n air is req uired  to o pe rate th is
heater. During operation the heater draws air for
combustion which can be assisted by the installation
of outsid e com bu stio n air inle ts.  Ho we ver, certain
weather conditions such as icing or use of kitchen
exhaust fans may impact and reduce the effectiveness
of vents. It is important to note that room air starvation
well negatively impac t the operation of the heater.

7.

If pow er outag es  with  batter y back up  or roo m  air
sta rva tion  occu rs during ope ration  of h ea ter, sm ok e in
the house may result.  This may trigger smoke
detectors if they are installed.

MAINTENANCE PROCEDURE

CAUTION:  MOVING PARTS MAY CAUSE INJURY, DO
NOT OPERATE WITH REAR COVER REMOVED.

WARNING:  RISK OF ELECTRICAL SHOCK,
DISCONNECT ALL POWER BEFORE SERVICING.

ALWAYS TURN YOUR Heater OFF & LET IT COOL
BEFORE CLEANING.

So ot a nd  Fly-a sh: Fo rm atio n an d N eed  for R em ov al.

The products of combustion will contain small particles of
fly-ash. The fly-ash will collect in the exhaust venting
system  and  restric t the flow  of the  flue gase s. Inc om plete
combustion, such as occurs during startup, shutdown, or
incorrect operation of the room heater will lead to some
soot formation which will collect in the exhaust venting
system. The exhaust venting system should be inspected
at le as t on ce  every year to determ ine if cle an ing is
necessary.Your EASYFIRE Pellet Heater requires routine
m aintenance for m axim um  perform ance an d is ma ndatory
for the warranty to remain in effect. The following
procedures should be studied carefully and performed
regularly as indicated:

1.

Fly Ash:

  Some ash will accumulate in the heat

exchanger, firepot and flue and should be cleaned out
on a  regu lar basis fo r bes t efficien cy and sa fety. 
W hen the heater is shut down and cold, you should:

a.

Open door and remove clean out slide cover. To
rem ove, s im ply slide up and out from  retaining angle
brac ke t (

Figure 10

). Clea n on e side  at a tim e. W ith

one slide cover rem oved, leave door ope n and turn
control knob to the 

"CLEAN"

 position. Let heater run

until ash in fire pot area is vacuumed out by heater
fan. Turn off and replace cover. Rem ove remaining
cover and repeat procedure for the other side.  The
tee cap on the vent pipe should be cleaned out after
this procedure.

b.

Rem ove firepot by lifting up and out, it may be
brushed out or vacuumed. Firepot should be cleaned
daily. Make sure holes in pot are not clogged.  The
area around and below the pot should be checked
every five or six days depen ding on how m any hours
a day you are burning your heater and the quality of
the  pellets  being burned .  (After a few  days you w ill
be able to determine the frequency needed for clean
out.)

c.

Scrape  pellet feed chu te with putty knife to rem ove
hardened material on which sawdust can
accumulate.

d.

The tee connector on the vent pipe must have a
clean ou t cap  and  this m ust b e ch eck ed e very four to
six weeks or whenever you utilize the clean out mode
on  the  control dial.

e.

Fly-ash can also accumulate in the vent pipe. Inspect
exhaust system frequently to maintain free flow of
exhaust fumes and fly-ash. The frequency of clean-
out depends entirely on the quality of the pellets, so
you will have to initially monitor the buildup in the
pellet vent pipe.  Those installations going into an

Summary of Contents for EasyFire EF-3801B-AL

Page 1: ...ype L Pellet Vent System NEVER use gasoline gasoline type lantern fuels kerosene charcoal lighter fluid or similar liquids to start or freshen up a fire Keep all such liquids well away from the heater...

Page 2: ...in all residential applications An outside air inlet MUST be provided for combustion and ventilation air The air inlet must remain unrestricted while unit is in use Outside air connection is located...

Page 3: ...3 Figure 3 Figure 4 Figure 5 Figure 6 c 2 ft minimum to an adjacent building and 7 ft minimum above grade when located adjacent to public walkways...

Page 4: ...emove factory jump wire and hook up thermostat wires to terminals Figure 7 8 c Locate thermostat approximately 10 to 12 feet from heater or in area that requires steady temperature d Run thermostat wi...

Page 5: ...deactivated and the stove operates based on the EasyFire digital control system requirements If the house AC power should quit the AutoLite system will not be available however with the optional batte...

Page 6: ...the stove will begin to heat up When the stove reaches start up operating temperature it will then switch to the control panel setting and begin it s automatic operation cycle Feed Trim Adjustment Und...

Page 7: ...spring to return against stop Figure 10 11 Once ash box is full box should be placed in a non combustible floor or on the ground well away from all combustible materials pending final disposal If the...

Page 8: ...equires routine maintenance for maximum performance and is mandatory for the warranty to remain in effect The following procedures should be studied carefully and performed regularly as indicated 1 Fl...

Page 9: ...ist for specifications TROUBLE SHOOTING The following scenarios are provided in order to help you locate a difficulty if the heater performs in a manner which would seem to indicate a malfunction l Pr...

Page 10: ...em when the hopper door is open If fuel is to be added while heater is in operation it must be accomplished with in several minutes of opening the door 9 Problem I turned off the switch and the heater...

Page 11: ...R 4 110451 ASH DUMP KNOB 5 300522 ASH DRAWER 6 200549 HEAT EXCHANGE COVER 7 300500 FIREPOT AL V2 8 120117 AUTOLITE IGNITER 9 202164 BURN POT SCREEN AL 10 120120 AUTOLITE POWER RELAY 11 120118 AUTOLITE...

Reviews: