1.

 

Select   a  locat ion  t hat   is  not   prone  t o 

moist ure and is located at  least  0.91m or 3 

feet   away  from  combust ible  mat erials  such 

as  curt ains  or  drapes,  furnit ure,  bedding, 

paper, et c. 

2.

 

M ark  t he  desired  locat ion  on t he  floor  and 

st ore appliance in a safe, dry and dust  free 

locat ion. 

3.

 

Prepare  a  wall  w it h  a  framed  opening  t o 

accommodat e t he size of your unit . Leave at 

least   1/4

  (6  mm)  around  t he  edge  of  t he 

appliance. Any new  w iring must  be done in 

compliance  w it h  local  and  nat ional  codes 

and ot her applicable regulat ions. 

 

Note

:  Fireplace  must   st ick  out   of  t he  wall  a 

minimum of 1/2

 or 1.5 cm. 

 

 

 

Prior  to  installing  the  appliance,  test  to  make 

sure  the  appliance  operates  properly  by 

plugging  the  pow er  supply  cord  into  a 

conveniently  located  120  Volt  grounded 

outlet. 

The rough wall opening size of t he fireplace: 

 

W(

D(

H(

WM -FM L-26-3223-STL

27 

6 1/2 

20 1/2 

WM -FM L-34-4023-STL

35 

6 1/2 

20 1/2 

WM -FM L-48-5523-STL

49 

6 1/2 

20 1/2 

WM -FM L-60-6623-STL

60 5/8 

6 1/2 

20 1/2 

WM -FM L-72-7823-STL

72 1/2 

6 1/2 

20 1/2 

WM -FM L-88-9623-STL

89 1/2 

6 1/2 

20 1/2 

 

 

1.

 

Take  the  front  panel off  from  the  unit.  Put  the 

brackets on the both sides and top of the fireplace 

as shown blew.

 

 

2.

 

Lift  fireplace and insert  int o opening. 

3.

 

M ake sure t hat  t he power supply port  is not 

behind t he wall. 

4.

 

Level t he fireplace. 

5.

 

Drive  mount ing  screws  int o  t he  mount ing 

bracket s on t he unit  and t he wall st uds. 

 

 

 

6    Replace the front panel and plug in back-

-lighting LED. See page 11.

Summary of Contents for WM -FM L-26-3223-STL

Page 1: ...STL SAFETY INFORMATION WARNING If the information in these instructions are not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance INSTALLER LEAVE THIS M ANUALWITH THE APPLIANCE CONSUM ER RETAIN THIS M ANUALFOR FUTURE REFERENCE ...

Page 2: ...KING AND TESTING APPLIANCE 4 GROUNDING APPLIANCE 4 LOCATING THE FIREPLACE 4 WM FML 34 4023 STL 6 WM FML 48 5523 STL 7 WM FML 60 6623 STL 8 WM FML 72 7823 STL 9 WM FML 88 9623 STL 10 REMOVING FRONT PANEL 11 INSTALLATION WALL MOUNT 12 INSTALLATION BUILT IN 13 HARD WIRE INSTALLATION 14 MEDIA OPTIONS 15 DECORATIVE MEDIA INSTALLATION 15 OPERATION 16 OPERATING WITH TOUCH PANEL 16 REMOTE CONTROL OPERATIO...

Page 3: ...o not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock fire or damage to the heater 10 To prevent a possible fire do not block air intakes in any manner 11 A heater has hot and arcing or sparking parts inside Do not use it in areas where gasoline paint or flammable liquids are used or stored 12 Use this heater only as described in this...

Page 4: ... is available To disconnect appliance turn controls to off then remove plug from outlet LOCATING THE FIREPLACE Plan where to locate and frame the fireplace This will save time and money later when you install the fireplace Before installation consider the following 1 Where the fireplace is located must allow for wall and ceiling clearances see INSTALLATION WALL MOUNT 2 Consider a location where th...

Page 5: ... Opening Size 27 20 1 2 or 68 60 cm 52 cm BTU 4800 This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada If you need assistance during installation please contact your local dealer NOTE This appliance must be electrically wired and grounded in accordance with local codes In the absence of loc...

Page 6: ...ll Opening Size 35 20 1 2 or 88 9 cm 52 cm BTU 4800 This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada If you need assistance during installation please contact your local dealer NOTE This appliance must be electrically wired and grounded in accordance with local codes In the absence of lo...

Page 7: ...l Opening Size 49 20 1 2 or 124 5 cm 52 cm BTU 4800 This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada If you need assistance during installation please contact your local dealer NOTE This appliance must be electrically wired and grounded in accordance with local codes In the absence of lo...

Page 8: ... Opening Size 60 5 8 20 1 2 or 154 cm 52cm BTU 4800 This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada If you need assistance during installation please contact your local dealer NOTE This appliance must be electrically wired and grounded in accordance with local codes In the absence of lo...

Page 9: ...pening Size 72 1 2 20 1 2 or 184 cm 52 cm BTU 4800 This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada If you need assistance during installation please contact your local dealer NOTE This appliance must be electrically wired and grounded in accordance with local codes In the absence of loc...

Page 10: ...ening Size 89 1 2 20 1 2 or 227 3 cm 52 cm BTU 4800 This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada If you need assistance during installation please contact your local dealer NOTE This appliance must be electrically wired and grounded in accordance with local codes In the absence of lo...

Page 11: ...ighting from the unit This plug is located at the bottom left hand side behind the front panel 2 The screws are located on the sides of the unit Once located unscrew the two or four screws You can then lift the front panel from the 4 shoulder posts on the sides of the unit and remove the front panel 3 To replace the front panel lift onto the 4 shoulder posts For a Wall Mount installation replace t...

Page 12: ... to ensure there is no wiring pipe wires etc in the area to be drilled Drill 8 or more holes 8mm diameter 40mm depth using a suitable size drill and put the wall plugs into the holes 4 Removemountingplatefrom thebackof theappliance by removing the two scews as shown in Fig 2 5 Referring to Fig 3 secure the mounting plate to the wall 6 Secure the fireplace to the wall using a screw Fig 4 Warning Be...

Page 13: ...ling the appliance test to make sure the appliance operates properly by plugging the power supply cord into a conveniently located 120 Volt grounded outlet The rough wall opening size of the fireplace W D H WM FM L 26 3223 STL 27 6 1 2 20 1 2 WM FM L 34 4023 STL 35 6 1 2 20 1 2 WM FM L 48 5523 STL 49 6 1 2 20 1 2 WM FM L 60 6623 STL 60 5 8 6 1 2 20 1 2 WM FM L 72 7823 STL 72 1 2 6 1 2 20 1 2 WM FM...

Page 14: ... electrically connected and grounded in accordance with local codes if hard wired In the absence of local codes use the current CSA C22 1 CANADIAN ELECTRICAL CODE in Canada or the current ANSI NFPA 70 NATIONAL ELECTRICAL CODE in the United States 1 Remove the cover plate from the left side of the appliance by removing the two screws as shown below Unscrew and remove power cord 2 Attach the wiring ...

Page 15: ...u finish installing the decorative media The only media that comes with this version is Clear decorative media Consumers may purchase optional decorative media if they choose See dealer for more details Removing the front panel NOTE Please unplug the power cord before you install the decorative media Remove the screws from both sides of the unit to take off the surround It is recommended that two ...

Page 16: ...multiple times to set operating duration to 30 min 1h 2h 3h 4h 5h 6h 7h 8h or off 4 Press multiple times to set ambient temperatures at When setting the temperature the number will flash Note The touch panel buttons will glow when pressed The light fades in 5 seconds after pressing ON OFF Power Flame Timer Heater Indicator 18 64 4 19 66 2 20 68 21 69 8 22 71 6 23 73 4 24 75 2 25 77 26 78 8 27 80 6...

Page 17: ...t ON OFF It has functions of setting memory DISPLAY BLUE button Adjust the blue color brightness of flame and tray DISPLAY YELLOW button Adjust the yellow color brightness of flame and tray DISPLAY ORANGE button Adjust the orange color brightness of flame and tray M OOD LIGHT ON OFF button Switching the mood light ON OFF ADJUST button Switching the color of the mood light FLASH button Switches the...

Page 18: ...thermostat prior to installing the fireplace WALL THERM OSTAT WIRING 24 VAC Install Wall Thermostat per instructions provided with kit and per the following information 1 Turn off circuit breaker 2 Remove cover plate located on the left side of appliance 3 Pull the wire out and cut the inside thermostat Connect the wires to the wall thermostat as shown below Follow instructions provided with wall ...

Page 19: ...ACK BLACK PLASTIC GLASS 1 9 3117505 BLOWER M OUNT 1 10 GLASSBRACKET 2 11 LED BRACKET 1 12 10702143 10702144 10702145 10702164 10702146 10702165 BOTTOM GLASS 1 13 10101225 FLAM E M OTOR 1 14 3093502 3094502 3095502 3120502 3096502 3122502 FLICKER ASSEM BLY 1 15 1 16 10103007 POWER CORD 1 17 BOTTOM PANEL 1 18 601136B 601136B 60 1137B 601136B 601136B 60 1137B 601137B 601136B 60 1137B FLAM E LED STRIP...

Page 20: ...20 EXPLODED VIEW ...

Page 21: ...plugged into an electrical outlet Check plug and plug in Appliance has overheated and safety device has caused the thermal switch to disconnect Turn off the main switch allow appliance to cool for 10 minutes then turn it on Appliance will not come on when switch is flipped to ON Circuit board is burnt out Inspect the circuit board and replace it if necessary No warm air coming out of appliance Hea...

Page 22: ...22 SERVICE HISTORY This heater must be serviced annually depending on usage Date Dealer Name Service technician Name Service Performed Special Concerns NOTES ...

Page 23: ...23 ...

Reviews: