Specifications
* Approximate shipping weight of transducer with standard cable length.
** EMC performance available upon request .
XLT-30
XLT-60
Measurement Range
0.9 - 30 m
(3 - 100 ft)
1.8 - 60 m
(6 - 200 ft)
Frequency
22 KHz
13 KHz
Beam Angle
5
5
Environmental
Location
indoor/outdoor
indoor/outdoor
Maximum Altitude
2000 m
2000 m
Ambient Temperature
-40 to 150
C
(-40 to 300
F)
-40 to 150
C
(-40 to 300
F)
Ambient Pressure
N. America: up to 1000 kPa (1 bar, 15 psi)
Europe: up to 50 kPa (0.5 bar, 7.25 psi)
Pollution Degree
4
4
Construction
Housing
aluminum, 304 stainless steel,
and silicon
aluminum, 304 stainless steel,
and silicon
Mounting
1" NPT conduit connection
1" NPT conduit connection
Cable
2-wire shielded/twisted,
0.5mm
2
(20 AWG) Silicone
jacket
2-wire shielded/twisted, 0.5mm
2
(20 AWG) PVC jacket
Weight**
6.6 kg
(14.5 lb)
6.6 kg
(14.5 lb)
Maximum separation
from transceiver
365 m
(1200 ft)
365 m
(1200 ft)
Supply Source
Transducers shall only be supplied by Siemens Milltronics
certified controllers
Approvals
CE**, CSA, FM, SIRA/CENELEC
,
INMETRO
See nameplate or consult Siemens Milltronics for current
approvals