5.
Put the service flap back on, lock it
into place and close it.
Note:
To prevent unused detergent
from flowing straight into the drain
during the next wash: Pour 2 litre of
water into dispenser
II
and start the
Single spin
programme.
The drain hose at the siphon
is blocked
1.
Turn the programme selector to
$
Off
. Pull out the mains plug.
2.
Loosen the hose clamp. Carefully
remove the drain hose; residual
water may leak out.
3.
Clean the drain hose and siphon
connecting piece.
4.
Re-attach the drain hose and secure
the connection point using the hose
clamp.
Filter in the water supply is
blocked
1.
Release water pressure in the supply
hose:
a) Turn off the tap.
b) Select any programme (except
Rinse
and
Spin
).
c) Select the
A
Start/Reload
button. Allow the programme to
run for approx. 40 seconds.
d) Turn the programme selector to
$
Off
. The appliance is switched
off.
e) Pull out the mains plug.
2.
Clean the filters:
a) Disconnect the hose from the
tap.
Clean the filter with a small brush.
b) For standard and Aqua-Secure
models, clean the filter on the
rear of the appliance:
Disconnect the hose from the
rear of the appliance.
Use pliers to remove the filter and
then clean it.
3.
Connect the hose and check for
leaks.