To make field connections, a device with a wire connector for field installed wiring shall be
provided with instructions specifying that the connector provided shall be used in making
field connections.
•
To power the device use 10-14 AWG solid or stranded wire, copper only..
2.7 Code and Standard References
•
The VersiComm enclosure meets requirements for the UL 508, NEMA 4 rating,
when seals are properly seated and antennas are properly installed. The door must
be fully closed and locked to maintain this rating and to avoid nullifying the
warranty. Any modifications to the enclosure, other than a NEMA 4 conduit hub
added for the power cabling, will nullify the commitment of the NEMA rating and
void the VersiComm warranty.
•
The VersiComm meets the stated operational temperature range of -25°C - 70°C
in an environment that has humidity between 5% ~ 95% relative humidity
(noncondensing).
•
Up to 25 VersiCharge SG chargers can be connected to the VersiComm in an
outdoor setting where no objects obstruct the direct connection to the VersiComm.
Large objects, those that scatter Wi-Fi signal, underground installations, especially
those near rebar and other location factors, can affect the VersiComm range.
•
The VersiComm’s uplink and downlink speeds are based on an outdoor installation
with no objects to interfere with the connection between the VersiComm antennas
and the nearest cellular antenna.