5.6.13 DR 7 - RS232 Printer Baudrate
If a printer is connected to the RS232 interface, the following baud rates can be
defined.
1200 Bit/sec
2400 Bit/sec
4800 Bit/sec
9600 bps
5.6.14 DR 7 - RS232 Transmission Control for Printer
The transfer control parameters for the RS232 interfaces can be defined as
follows:
XON/XOFF (for printer protocol only)
0: XON/XOFF transmission control OFF
1: XON/XOFF transmission control ON
RTS/CTS (for printer protocol only)
0: CTS/RTS transmission control OFF
1: CTS/RTS transmission control ON
5.6.15 DR 7 – Protocol Selection for RS 485
The following protocols can be set for the RS485 interface
- 0: No protocol
1: SIEBERT- Protocol S11
2: ASCII protocol
3: SIEBERT- Protocol S102 (6-position)
5.6.16 DR 7 - Decimal Place for the Remote Display
If a display from the Siebert company is connected to the RS 485 interface,
the decimal place for the display of non-verifiable process values can be defined.
5.6.17 DR 7 – RS 485 Baudrate
The following protocols can be set for the RS485 interface:
0 = 1200 Bit/sec.
1 = 2400 Bit/sec.
2 = 4800 Bit/s
3 = 9600 Bit/s
4 = 19200 Bit/s