![Siemens SIWAREX FTC Device Manual Download Page 37](http://html.mh-extra.com/html/siemens/siwarex-ftc/siwarex-ftc_device-manual_1265490037.webp)
H
ARDWARE
C
ONFIGURATION AND
A
SSEMBLY
When connecting a single display, ensure that the RTa and RTb bridges are wired.
When installing the S102 for operation, the same parameters that have been set by
the SIWATOOL FTC for RS 485 are to be defined.
Figure 4-11
Connecting the S102 display
4.4.13 Connecting the PC for SIWATOOL FTC
Table
RS 232 Interface
Termination Clamp
Signal
Comment
X2
9 pin D-type
RS 232 Interface
Table 4-10
Connecting the PC
Ready-made cables are available for connecting the PC (see
)
Figure 4-12
Connecting the PC
SIWAREX FTC