Start Up
8.7 Load cell replacement
SITRANS WW310
Operating Instructions, 03/2014, A5E33490433-AA
29
①
Load cell
④
Overload screw
②
Bottom load cell mount
⑤
Top/front load cell mount
③
Shipping screw
Note
Load cell may appear different than shown.
Step 3
Support the scale idler/deck from below or above, and remove the two top/front load cell mount
bolts. Be careful not to move the idler as it is still attached to the load cell on the other side of the
weighfeeder.
Step 4
Remove the two bottom load cell mount bolts.
Step 5
Remove the load cell off the feeder.