Mechanical installation
5.1 Installation
SITRANS WW310
14
Operating Instructions, 03/2014, A5E33490433-AA
5.1
Installation
Note
•
Only qualified personnel are authorized to install and operate this equipment. Installation
shall be in accordance with local regulations, standards and established safety practices.
Read and understand the instructions before installing, operating or maintaining the
equipment.
•
Flexible in-feed connections are REQUIRED for all applications. Flexible discharge
connections are also recommended.
Step 1
Construct the necessary support framework to provide a sturdy, rigid base. Vibration isolators
are recommended if the location is subject to moderate or heavy vibration.
Step 2
Align the in-feed section of the weighfeeder with the discharge of the feed device. Prevent
twisting or misalignment that could induce stress on the weighing section.
Step 3
Install a gasket between the flanges for dust control.
Step 4
Securely fasten the unit to the rigid, level structure constructed in Step 1 (Page 14). Use a level
for verification and shim as necessary. Prevent any twisting of the frame that may affect
weighfeeder performance.
Note
The inlet and discharge of the weighfeeder will not support load.
Summary of Contents for SITRANS WW310
Page 1: ...SITRANS Weighfeeders SITRANS WW310 Operating Instructions 03 2014 ...
Page 8: ...Introduction 1 1 The Manual SITRANS WW310 6 Operating Instructions 03 2014 A5E33490433 AA ...
Page 14: ...Operation 4 1 Weighfeeders SITRANS WW310 12 Operating Instructions 03 2014 A5E33490433 AA ...
Page 20: ......
Page 22: ...Calibration 6 3 Span SITRANS WW310 20 Operating Instructions 03 2014 A5E33490433 AA ...
Page 24: ...Wiring SITRANS WW310 22 Operating Instructions 03 2014 A5E33490433 AA ...
Page 47: ......