Mechanical installation
5.1 Installation
SITRANS WW310
Operating Instructions, 03/2014, A5E33490433-AA
15
Step 5
Note
If your system has a permanently lubricated gear motor, then disregard this step, and
proceed directy to Step 6 (Page 15).
Check the gear reducer oil level. See the gear reducer information for further details on
maintenance.
Step 6
A de-dust port is provided on enclosed units at the discharge end. If no de-dust system is
required, this port should be closed.
Step 7
Connect the proper electric supply to the motor and/or motor controller. The AC or DC motor
controller (if present) must be grounded to minimize noise to the electronic integrator. Refer to
the applicable wiring diagram to make all electrical connections between the electronic integrator
and the weighfeeder.
Note
Units with a plugged discharge switch should refer to the wiring diagram included in the
CLS100 manual.
Step 8
Remove only the tagged shipping bolt that is attached to the load cell. This bolt supports the
weighbridge during transport and installation.
Note
DO NOT loosen or tighten the overload bolt—it has been factory set to minimize the
possibility of load cell damage resulting from incidental overload.
Summary of Contents for SITRANS WW310
Page 1: ...SITRANS Weighfeeders SITRANS WW310 Operating Instructions 03 2014 ...
Page 8: ...Introduction 1 1 The Manual SITRANS WW310 6 Operating Instructions 03 2014 A5E33490433 AA ...
Page 14: ...Operation 4 1 Weighfeeders SITRANS WW310 12 Operating Instructions 03 2014 A5E33490433 AA ...
Page 20: ......
Page 22: ...Calibration 6 3 Span SITRANS WW310 20 Operating Instructions 03 2014 A5E33490433 AA ...
Page 24: ...Wiring SITRANS WW310 22 Operating Instructions 03 2014 A5E33490433 AA ...
Page 47: ......