Technical data
8.3 Effect of temperature on working pressure
41
Coil cable
Standard electrode
cable
Media temperature:
< 100 °C
40 Ω
N/A
Max. cable loop resistance
> 200 °C
6 Ω
N/A
M20x1.5 gland - Cable ø 5 ... 13 mm (0.20 ... 0.51 inches)
Cable glands on sensor
and transmitter
½ NPT gland - cable ø 5 ... 9 mm (0.20 ... 0.35 inches)
Special applications, e.g. low conductivity or electrical noise
Table 8- 7
Technical data, special application cables
Coil cable
Special electrode cable
No. of conductors
3
3
Sqr. area
1.5 mm
2
0.25 mm
2
Shield
Yes
Double
Color code
Brown, blue, black
Brown, blue, black
Outside color
Grey
Grey
Ext. diameter
7.8 mm
8.1 mm
Conductor
Flexible CU
Flexible CU
Basic data
Isolation material
PVC
PVC
Flexible installation
-5 ... +70°C
(23 ... 158°F)
-5 ... +70°C
(23 ... 158°F)
Ambient temperature
Non-flexible installtaion
-30 ... +70°C
(-22 ... 158°F)
-30 ... +70°C
(-22 ... 158°F)
Capacity
161.50 pF/m
N/A
Inductance
0.583 μH/m
N/A
Cable parameter
L/R
43.83 þH/Ω
N/A
8.3
Effect of temperature on working pressure
Effect of temperature on working pressure.
Table 8- 8
Metric measures (pressure in bar)
Temperature (°C)
Flange
specifications
Flange rating
-5
10
50
90
Sizes DN25 ... 2000
PN 10
10.0
10.0
9.7
9.4
PN 16
16.0
16.0
15.5
15.1
EN 1092-1
PN 40
40.0
40.0
38.7
37.7
ANSI B16.5
150 lb
19.7
19.7
19.3
18.0
AWWA C-207 Class D
10.3
10.3
10.3
10.3
www.eltra-trade.com [email protected]
+421 552 601 099