Description
3.2 Theory of operation
12
The SITRANS F M MAG 5100 W sensor housing and flanges are designed in carbon steel
and terminal box in fibre glass reinforced polyamide. Measuring pipe is made of stainless
steel (AISI 304) and liners are available in NBR Hard Rubber, Ebonite Hard Rubber, or
EPDM, which makes the sensor highly resistant to a wide range of chemicals. Electrodes are
made of Hastelloy.
MAG 5100W DN15 ... 40
MAG 5100W DN50 ... 300
MAG 5100W DN350 ... 1200
(7ME6520)
MAG 5100W DN25 ... 2000
(7ME6580)
MAG 5100W compact
installation with MAG
5000/6000 IP67
MAG 5100W compact
installation with MAG 6000 I
The sensors carry a wide range of approvals, see Technical data (Page 37).
3.2
Theory of operation
The flow measuring principle is based on Faraday’s law of electromagnetic induction.
0DJQHWLF)LHOG
)ORZ
www.eltra-trade.com [email protected]
+421 552 601 099