Modbus communication
A.9 Modbus holding registers tables
SITRANS F Ultrasonic flowmeters FST030 (Modbus)
Operating Instructions, 08/2017, A5E37367739-AC
289
Sensor cassette
Table A- 86 Sensor cassette
Modbus
register
Data type /
Size in bytes
Parameter
Description
Default value
[unit]
(unit register)
Value range /
Setting options
Access
level
4135
String / 10
HW version
Hardware version of
the cassette.
-
-
Read
only
4020
String / 10
FW version
Firmware version of
the cassette.
-
-
Read
only
4145
String / 32
Serial number
Serial number of the
cassette.
-
-
Read
only
Sensor
Table A- 87 Sensor
Modbus
register
Data type /
Size in bytes
Parameter
Description
Default value
[unit]
(unit register)
Value range /
Setting options
Access
level
4010
String / 16
Sensor type
Name of the sensor.
-
-
Read
only
4210
String / 20
Frontend serial
number
Serial number of front
end.
-
-
Read
only
4033
String / 20
Sensor serial
number
Sensor serial number
of inline sensor.
-
-
Read
only
4043
String / 20
Sensors serial
number path 1
Serial number of sen-
sor set path 1 (clamp-
on).
-
-
Read
only
4053
String / 20
Sensors serial
number path 2
Serial number of sen-
sor set path 2 (clamp-
on).
-
-
Read
only
4063
String / 20
Sensors serial
number path 3
Serial number of sen-
sor set path 3 (clamp-
on).
-
-
Read
only
4073
String / 20
Sensors serial
number path 4
Serial number of sen-
sor set path 4 (clamp-
on).
-
-
Read
only
1300
Unsigned / 2 Sensor type
Type of sensor.
-
•
0: FSS200 (Clamp-
on)
•
1: FSS300 (Inline,
SONO3100/3300)
•
2: FSS300 retrofit
(Inline, SONOKIT)
•
FSS600 (Clamp-on
spool, FUT1010)
•
FSS400 (Oil, inline)
Read