SITRANS F C MASSFLO
2
SFIDK.PS.028.Q1.02
Contents
1.
Introduction
..................................................................................................................................... 2
2.
Installation
....................................................................................................................................... 3
2.1
Compact ............................................................................................................................................ 3
2.2
Remote ............................................................................................................................................. 3
2.3
Ex survey according to Directive 94/9/EC (ATEX) ........................................................................... 4
2.4
Overview ........................................................................................................................................... 5
2.5
Device identification .......................................................................................................................... 6
2.6
Approvals .......................................................................................................................................... 7
2.7
Special conditions for safe use of MASS 6000 Ex-d version and MASS 2100 ............................... 7
2.8
Mounting of signal converter compact or remote ............................................................................. 8
2.9
Display and keypad .......................................................................................................................... 8
3.
Electrical connection
..................................................................................................................... 9
3.1
Electrical connection compact or remote ......................................................................................... 9
3.2
Setting of active or passive current out-put mode ........................................................................... 11
3.3
SENSORPROM
unit ...................................................................................................................... 11
3.4
Installation of add-on module (AOM) ............................................................................................. 12
3.5
Installation examples ...................................................................................................................... 13
4.
Technical data
............................................................................................................................... 14
4.1
Sensor MASS 2100. Versions DI 1.5, DI 3, DI 6, DI 15, DI 25, DI 40 ........................................... 14
4.2
Signal converter MASS 6000 Ex-d ................................................................................................. 15
4.3
Output characteristic MASS 6000 .................................................................................................. 17
5.
Commissioning
............................................................................................................................. 18
5.1
Keypad and display layout .............................................................................................................. 18
5.2
Menu build-up ................................................................................................................................. 19
5.2.1
Password ........................................................................................................................................ 19
5.3
Menu overview ................................................................................................................................ 20
5.4
Menu details ................................................................................................................................... 21
5.5
Outputs setting menu ..................................................................................................................... 22
5.6
Reset mode .................................................................................................................................... 24
6.
Service
........................................................................................................................................... 25
6.1
List of error numbers ...................................................................................................................... 25
6.2
Trouble shooting MASS 6000 ......................................................................................................... 26
7.
Ordering
......................................................................................................................................... 27
7.1
Build-up ordering ............................................................................................................................ 27
7.2
Build-up ordering - High pressure versions .................................................................................... 28
7.3
Signal converter MASS 6000 Ex-d for remote mounting ............................................................... 29
7.4
Accessories for MASS 6000 Ex-d and MASS 2100 ....................................................................... 29
8.
Certificates
.................................................................................................................................... 30
8.0
Download certificates ..................................................................................................................... 30
8.1
EU-declaration of conformity ......................................................................................................... 30
8.2
EC type examination certificate ...................................................................................................... 31
1.
Introduction
For safety reasons it is important that the following points, especially the points marked with
a warning sign, are read and understood before the system is being installed:
•
Installation, connection, commissioning and service must be carried out by personnel
who are qualified and authorized to do so.
•
It is very important that the same people have read and understand the instructions and
directions provided in this manual and that they follow the instructions and directions
before taking the equipment into use!
•
People who are authorized and trained by the owner of the equipment may operate the
equipment.
•
The installation must ensure that the measuring system is correctly connected and is
in accordance with the connection diagram. The signal converter has to be earthed
unless the power supply is galvanically isolated.
•
In applications with working pressures/media that can be dangerous to people,
surroundings, equipment or others in case of pipe fracture, we recommend that special
precautions such as special placement, shielding or installation of a security guard or
a security valve should be made when the sensor is being installed.
•
Siemens Flow Instruments want to assist by estimating the chemical resistance of the
sensor parts that are in connection with the media, but it is at any time the customer’s
responsibility, which materials are chosen and Siemens Flow Instruments takes no
responsibility if the sensor corrodes!
It is required that the special directions provided in the manual and in the Ex certificate
must be followed!
•
Installation of the equipment must comply with national regulations.
Example EN 60079-14 for Denmark.
•
Repair and service can be done by approved Siemens Flow Instruments personnel only.
- this page has been updated 2004.01