SITRANS F C MASSFLO
12
SFIDK.PS.028.Q1.02
3. Electrical connection
Disconnect
the equipment from the supply
circuits and wait 30 min. for dischanging the
energy in the internal electronics before
opening.
Remove the rear cover, by loosening the safety
tap allen screw (M3) and turn the rear cover
counter-clockwise.
Remove the electronics using the holes provided.
The add-on module is fitted at the bottom of the
converter insert as shown. The label text on
the add-on module should face upwards as
shown.
The add-on module is fitted with the connector
facing outwards of the enclosure.
Only HART or Profibus
are alloved to be
used. Please look into technical data page 11.
The add-on module can be pressed into posi-
tion.
Connect the flat cable connector to the module
and power up. The add-on module is auto-
matically initialised. The menu's are now
visable on the display/keypad of the MASS
6000.
Remove the flat cable from the plate.
Remove the plate from the module bay.
3.4 Installation of
add-on module (AOM)
View C
EEx d