4.3.2
Transport and Storage Conditions
Components in original packaging
The following specifications apply to components in transport packaging:
Transport
Storage
Standard / class
EN 60721-3-2
EN 60721-3-1
Temperature range
-20 ... + 60 °C
-25 ... + 55 °C
Temperature change
-40 °C/+30 °C and +70 °C/+15 °C
*)
< 0.5 K / min (≙ 30 K / h)
averaged over 5 minutes
Relative humidity
5 ... ~95%
10 ... 100 %
Permissible change of the rel‐
ative humidity
max. 0.1% / min (≙ 6% / h)
*)
A direct change between the specified temperatures in the air is assumed
Table 4-2
Transport values for PPU
Vibratory load:
● Operation (3M1)
● Package (1M2)
9 - 29 Hz: 0.3 mm; 29 - 200 Hz: 1g
5 - 9 Hz: 3.5 mm, 9 - 200 Hz: 1 g
Shock load:
● Operation (3M1)
5 g, 30 ms
Product packaging
1M2
4.3.3
Operating Conditions
Note
Before commissioning components with display, remove the foil which is used to protect the
components during transport.
Climatic environmental conditions of PPU 1740-1500 and PPU 1740-1900
Parameters
Values
Limit temperatures at 100% load
0 ... 40 °C (front)
0 ... 45 °C (rear)
Temperature change
< 0.5 K / min (≙ 30 K / h) averaged over 5 minutes
Humidity
Relative: 5 … 90 %
Permissible change of the relative humidity
max. 0.1%
min (≙ 6% / h)
Application planning
4.3 Climatic and mechanical environmental conditions
PPU 1740
Equipment Manual, 01/2019, A5E47615272B AA
47
Summary of Contents for SINUMERIK ONE PPU 1740 Series
Page 22: ...System overview 2 2 System configuration PPU 1740 22 Equipment Manual 01 2019 A5E47615272B AA ...
Page 82: ...Interface description 7 7 USB PPU 1740 82 Equipment Manual 01 2019 A5E47615272B AA ...
Page 92: ...Connectable components 8 1 NX10 3 NX15 3 PPU 1740 92 Equipment Manual 01 2019 A5E47615272B AA ...
Page 100: ...Spare parts and accessories PPU 1740 100 Equipment Manual 01 2019 A5E47615272B AA ...