Technical Appendix
6.1
List of machine and setting data
6-103
SINUMERIK 802C
6FC5 597–3AA20–0BP2 (01.02)
36300
ENC_FREQ_LIMIT
Hz
Encoder limit frequency
POWER ON
_always
300000
0
plus
DOUBLE
2/7
36302
ENC_FREQ_LIMIT_LOW
%
Encoder limit frequency at which encoder is switched on again. (Hysteresis)
NEW CONF
_always
99.9
0
100
DOUBLE
2/7
36310
ENC_ZERO_MONITORING
-
Zero mark monitoring (encoder no.): 0,1
0: Zero mark monitoring off, encoder HW monitoring on
1-99, >100: Number of recognized zero mark errors during monitoring
100: Zero mark monitoring off, encoder HW monitoring off
NEW CONF
_always
0, 0
0.0
plus
DWORD
2/7
36400
CONTOU_TOL
mm, deg.
Contour monitoring tolerance band
NEW CONF
_always
1.0
***
***
DOUBLE
2/2
36500
ENC_CHANGE_TOL
mm, deg
Portion of distance for backlash working
NEW CONF
_always
0,1
0.0
plus
DOUBLE
2/7
36610
AX_EMERGENCY_STOP_TIME
s
Duration of the deceleration ramp for error states
NEW CONF
_always
0.05
0.0
plus
DOUBLE
2/7
36620
SERVO_DISABLE_DELAY_TIME
s
Cutout delay servo enable
NEW CONF
_always
0.1
0.0
plus
DOUBLE
2/7
36700
DRIFT_ENABLE
-
Automatic drift compensation
NEW CONF
_always
0
***
***
BOOLEAN
2/7
36710
DRIFT_LIMIT
%
Drift limit value for automatic drift compensation
NEW CONF
_always
1.000
0.0
plus
DOUBLE
2/7
36720
DRIFT_VALUE
%
Drift basic value
NEW CONF
_always
0.0
DOUBLE
2/7
38000
MM_ENC_COMP_MAX_POINTS
-
Number of intermediate points for interpolatory compensation (SRAM)
POWER ON
_always
0, 0
0
5000
DWORD
2/7
6.1.5
Setting data
Number
MD Name
Unit
Name, Miscellaneous
Activated
HW / function
Standard value
Minimum value
Maximum value
D type
User
class
41110
JOG_SET_VELO
mm/min
Axis speed for JOG
Immediately
_always
0.0
0.0
plus
DOUBLE
4/4
41200
JOG_SPIND_SET_VELO
rev/min
Speed for spindle JOG mode
Immediately
_always
0.0
0.0
plus
DOUBLE
4/4
Summary of Contents for SINUMERIK 802C
Page 1: ...Start Up 01 2002 Edition SINUMERIK 802C ...
Page 2: ......
Page 8: ...Table of Contents viii SINUMERIK 802C 6FC5 597 3AA20 0BP2 01 02 notice ...
Page 40: ...Installing the Drives 3 40 SINUMERIK 802C 6FC5 597 3AA20 0BP2 01 02 ...
Page 138: ...Index Index 138 SINUMERIK 802C 6FC5 597 3AA20 0BP2 01 02 notice ...
Page 140: ......