Configuring with Web Based Management
4.6 System
SINEMA Remote Connect - Server
50
Operating Instructions, 11/2017, C79000-G8976-C383-04
Configuring the interface
Make the following settings in the "Interfaces" tab. Then click the "Save" button:
Box
Meaning
Activate the inter-
face
The WAN interface cannot be deactivated.
The LAN interfaces are optional and can be disabled.
Interface
Select the interface to be configured.
If you select the WAN interface, additional entries are necessary, refer to the
table "Additional settings for the WAN interface".
MAC address
Displays the MAC address of the selected interface. Is entered automatically by
the system.
MTU
MTU (Maximum Transmission Unit) specifies the maximum size of the packet.
If packets are longer than the set MTU they are fragmented.
Maximum size 1500 bytes.
Enter a value ≤ 1 500.
IP address
Enter the IP address of the interface. The IP address must be unique.
Network mask
Enter the subnet mask of the subnet you are creating.
Additional settings for the WAN interface
Box
Meaning
Default gateway
When operating a VPN over the Internet, additional IP addresses are
generally required for the Internet gateways such as DSL routers. In
the VPN, the individual modules must know the public IP addresses
of the partner modules to be reached via the Internet.
Enter the IP address for the gateway.
SINEMA Remote Connect is
located behind a NAT device.
When you activate the button, you can enter the external WAN IP
address for the Internet gateway.
WAN IP address
The WAN IP address via which SINEMA RC can be reached. This
can, for example, be the WAN IP address of a DSL router via which
SINEMA RC is connected to the Internet.