Installation and commissioning
3.2 Installing SINEMA RC Server
SINEMA Remote Connect - Server
28
Operating Instructions, 11/2017, C79000-G8976-C383-04
System update V1.2 > V1.3
●
Check the firmware version of the devices
Before updating the server, ensure that the firmware versions of the connected
SCALANCE M-800 / S615 devices are compatible.
●
Check the SINEMA RC Client version
Before updating the server, check the version of the SINEMA RC Client. Click "?" in the
selection area and select the menu command "Info".
A SINEMA RC Client with a version < V1.0 SP3 cannot connect to a SINEMA RC Server
>= V1.3. Update the SINEMA RC Client.
Procedure
1.
Back up your configuration using SINEMA RC Server V1.2 WBM and export this backup
file to your PC or SFTP server. You can find more detailed information on this in the
sections "Backup & Restore (Page 61)" and "Server upload (Page 60)".
2.
Insert the V1.3 data medium into the drive.
3.
Perform a restart from the "Energy Management (Page 59)" WBM page. Installation starts
automatically.
4.
Select the "Install/Update SINEMA Remote Connect Server" entry in the following dialog.
Confirm the selection with the Enter key.