Parameter
ID
Unit
Default
Min
Max
Description
Regen Shift Angle
2625
deg
0.00
-11.25
11.25
Regen angle adjustment.
1
DC Bus Reference
2626
%
100
Sets the AFE cell DC Bus reference value.
Possible selections are 100%, 101%, 102%,
103%, 104%, 105%.
NOTE: This parameter applies ONLY for Cell
Voltage type 600 AP AFE (PWM regen).
* -181 indicates that AP cells are not installed on this rank.
1
Default values are recommended.
Table 6-18
Synchronous Transfer Menu (2700) Parameters
Parameter
ID
Unit
Default
Min
Max
Description
Phase I gain*
2710
2.0
0.0
15.0
Phase integrator gain
Phase P gain*
2720
4.0
0.0
12.0
Phase proportional gain
Phase offset
2730
deg
2.00
-90.00
90.00
Specify the phase angle setpoint used dur‐
ing up transfer. This is set positive and ex‐
pressed in degrees leading to prevent power
flow back into drive.
Frequency offset
2750
%
0.5
-10.0
10.0
Frequency offset used during down transfer
to establish torque current by driving the
speed regulator into limit.
Up transfer time‐
out
1
2760
sec
0.0
0.0
600.0
If the time taken for up transfer exceeds this
value then an up transfer timeout fault is
generated.
Ensure this setting is greater than the accel‐
eration time setting (2270, 2290, or 2310).
Set to 0 to disable the timeout fault.
Up transfer
threshold
2762
%
5.0
0.0
15
current instability threshold when line con‐
tactor closes
Down transfer
timeout
2
2770
sec
0.0
0.0
600.0
If the time taken for down transfer exceeds
this value then a down transfer timeout fault
is generated. This is unaffected by the accel‐
eration rate. Set to 0 to disable the timeout
fault.
Down transfer
threshold
2772
%
5.0
0.0
15
motor voltage droop when line contactor
opens
Sync transfer type 2775
with Reac‐
tor
Selects sync transfer with or without a reac‐
tor
"with Reactor"
"No Reactor"
Parameter Assignment/Addressing
6.5 Options for Drive Menu (2) - first part
Control Manual
Operating Manual, A5E50491925A
111
Summary of Contents for SINAMICS PERFECT HARMONY GH180
Page 2: ......
Page 22: ...Table of contents NXGPro Control Manual 20 Operating Manual A5E50491925A ...
Page 24: ...Security NXGPro Control Manual 22 Operating Manual A5E50491925A ...
Page 504: ...NEMA Table NXGPro Control Manual 502 Operating Manual A5E50491925A ...
Page 517: ...Index D NXGPro Control Manual Operating Manual A5E50491925A 515 ...
Page 518: ...Index NXGPro Control Manual 516 Operating Manual A5E50491925A ...
Page 530: ...Glossary NXGPro Control Manual 528 Operating Manual A5E50491925A ...
Page 537: ......