12.96
Technical Data
Siemens AG 6SE7087-6BM70
9-1
SIMOVERT MASTER DRIVES Operating Instructions
9
Technical Data
The drive converters correspond to the listed conditions as well as the specified domestic and international
standards.
Switching at the input
No./min
2
Cooling medium temperature
0 °C to +40 °C
Storage temperature
−
25 °C to +70 °C
Transport temperature
−
25 °C to +70 °C
Environmental class
3K3
DIN IEC 721-3-3
Moisture condensation not permissible
Pollution level
2
DIN VDE 0110 Pert 1
Overvoltage category
III
DIN VDE 0110 Part 2
Overvoltage property class
1
E DIN VDE 0160
Protection class
I
DIN VDE 0106 Section 1
Radio interference level
−
standard
without
DIN VDE 0875 Section 11 =
^ EN 55011
Noise immunity
EN50082-2
Mechanical strength
DIN IEC 68-2-6 / 06.90
Frequency range
Constant amplitude of the
deflection
acceleration
Hz
mm
m/s
2
(g)
−
when stationary (in op.)
10 to 58
above 58 to 500
0.075
9.8 (1)
−
during transport
5 to 9
above 9 to 500
3.5
9.8 (1)