Description of the motors
2.3 Technical features and ambient conditions
1FW68 radial segment motors
Configuration Manual, 04/2017, 6SN1197-0AE02-0BP1
37
2.3.5
Ambient conditions for stationary use
Based on DIN EN 60721-3-3 (for stationary use at weather-protected locations)
Table 2- 2
Climatic ambient conditions
Lower air temperature limit:
- 5 °C (deviates from 3K3)
Upper air temperature limit:
+ 40 °C
Lower relative humidity limit:
5 %
Upper relative humidity limit:
85 %
Rate of temperature fluctuations:
Max. 0.5 K/min
Condensation:
Not permissible
Formation of ice:
Not permissible
Stationary use:
Class 3K3
Devices can only be operated in locations that are fully protected against the weather (in halls or rooms).
Table 2- 3
Biological ambient conditions
Stationary use:
Class 3B1
Table 2- 4
Mechanically active ambient conditions
Stationary use:
Class 3S1
Table 2- 5
Mechanical ambient conditions
Stationary use:
Class 3M3
2.3.6
Scope of delivery
2.3.6.1
Segment motors
Segment motors are only available in the form of individual components:
●
Stator segments
●
Rotor segments
●
Connecting cables
T-sliding blocks to fix rotor and stator segments are not available.