Configuring
5.1 Configuring workflow
1FW68 radial segment motors
Configuration Manual, 04/2017, 6SN1197-0AE02-0BP1
89
5.1.9
Torque-speed requirements
Fulfilling the torque-speed requirements
If the selected torque motor cannot fulfill the torque-speed requirements, the following
options are available:
●
Larger motor
If an operating point in the range A is required, a motor with a larger diameter and/or
longer length is required (see motor 2 in the following diagram).
Advantage: Higher torques are available.
Disadvantage: A larger motor installation space is required.
Figure 5-7
Requirement: larger motor
●
Motor with faster winding
If an operating point in the range B is required, a motor with a lower phase inductance is
required (see motor 2 in the following diagram).
Advantage: Higher speeds are possible.
Disadvantage: A higher motor current is required.
Figure 5-8
Requirement: lower phase inductance