Operation
8.7 faults
1LE5, 1PC4 shaft height 315/355
88
Operating Instructions, 10/2020, A5E41454666A
8.7.2
Electrical faults
Note
If you are operating the motor with a converter, the operating instructions of the converter
must also be observed if electrical faults occur.
Table 8- 1
Electrical faults
↓
Motor fails to start
↓
Motor accelerates sluggishly
↓
Rumbling noise during startup
↓
Rumbling noise during operation
↓
High temperature rise during no-load operation
↓
High temperature rise with load
↓
High temperature rise of individual winding sections
Possible causes of faults
Remedial measures
X X
X
X Overload
Reduce the load.
X
Interrupted phase in the supply cable
Check the switches and cables.
X X X
X Interrupted phase in the feeder cable
after switching on
Check the switches and cables.
X
Mains voltage too low, frequency too
high
Check the power supply conditions.
X
Mains voltage too high, frequency too
low
Check the power supply conditions.
X X X X
X Stator winding incorrectly connected
Check the winding connection in the terminal
box.
X X X
X Winding short circuit or phase short
circuit in stator winding
Determine the winding resistances and insula-
tion resistances. Carry out repair work
after
consultation with the manufacturer
.
X Incorrect direction of rotation
Check the connection.