![Siemens SIMOTICS SD 1LE5 Operating Instructions Manual Download Page 108](http://html.mh-extra.com/html/siemens/simotics-sd-1le5/simotics-sd-1le5_operating-instructions-manual_379065108.webp)
Maintenance
9.3 Corrective maintenance
1LE5, 1PC4 shaft height 315/355
106
Operating Instructions, 10/2020, A5E41454666A
9.3.8
Reassembly: Miscellaneous information
•
Position all rating and supplementary plates as in the original state.
•
Where relevant, fix electric cables.
•
Check the tightening torques of all screws, as well as those of screws that have not been
released.
9.3.9
Optional add-on units
Note
Further documents
Observe all of the other documents provided with this machine.
You can find additional operating instructions here:Further documents (Page 124)
9.3.9.1
Mounting a brake (optional)
Table 9- 5
Assigning standard brakes for 1LE5 machines
Frame size
(FS)
Brake type
Size assignment of the
brakes
315
SFB 250-SH
250
355
SFB 400-SH
400
9.3.10
O-ring seal
If O-ring seals are present, you should check that they are in perfect condition and that the O-
ring seals are properly seated in the grooves between the components. Replace damaged O-
ring seals.
O-ring seals can be present on the following components, for instance:
•
Adapters, tapers
•
Entries, glands
•
Bearing seals
•
End shield seals
•
Terminal box sealing
•
etc.