Maintenance
9.3 Corrective maintenance
1LE5, 1PC4 shaft height 315/355
104
Operating Instructions, 10/2020, A5E41454666A
13.
Install the outer bearing cover if one is being used.
14.
Install the sealing elements:
See also
Replacing rolling bearings (Page 108)
9.3.2
Mounting dimension "x"
Mounting dimension "x" of V rings
Shaft height
x
mm
315
13.5 ±1.2
Standard design
Special design
355
•
Extreme caution and attention to the correct positioning are vital during installation and
assembly.
•
Make sure the sealing surface is free of dirt and damage.
•
Lightly grease the sealing lips.
9.3.3
Fan
9.3.3.1
Metal fan disassembly
Metal fan
•
Shaft height 63: Release the two M4 clamping screw so that the fan can rotate freely on
the shaft.
•
Shaft heights 71...90: Release the M5 set screw so that the fan can rotate freely on the
shaft.
•
Shaft height 100...355: Remove the locking ring.
•
Use a suitable tool to pull off the fan (puller).
•
Locate the arms of the pulling tool in the openings in the fan in the vicinity of the hub.