4.5
Interlock circuit for anti-condensation heating (option)
If the anti-condensation heating is operated while the machine is running, this can increase
the temperatures inside the machine.
● Install an interlock circuit that switches off the anti-condensation heating once the main
machine is switched on.
● Only switch on the anti-condensation heating after the machine has been switched off.
See also
Avoidance of condensation or formation of condensation within the machine (Page 91)
4.6
Thermal motor protection
The machine is equipped as standard with two KTY 84 temperature sensors, optionally with
six PT100 to directly monitor the motor temperature to protect the machine against overload
in operation. Plan a corresponding circuit for monitoring.
4.7
Noise emissions
Noise emissions
During operation, the machine's noise emission levels can exceed those permitted at the
workplace, which can cause hearing damage.
● Ensure that nobody is in the area of increased noise emissions during machine operation.
● Take steps to reduce noise so that the machine can be operated safely within your system.
The following measures may help to reduce noise.
– Covers
– Noise insulation
– Hearing protection measures
4.8
Rotational speed limit values
Excessive rotational speed can lead to serious damage to the machine and the converter. This
can result in death, serious injury or material damage.
● The converter control must ensure that operation at impermissible speeds is prevented.
● Please note the speed data specified in the Electrical Data.
Preparations for use
4.5 Interlock circuit for anti-condensation heating (option)
SIMOTICS HT Series HT-direct 1FW4...1......A
Operating Instructions 11/2018
31
Summary of Contents for SIMOTICS HT Series
Page 2: ...13 11 2018 16 25 V5 00 ...
Page 10: ...Table of contents SIMOTICS HT Series HT direct 1FW4 1 A 10 Operating Instructions 11 2018 ...
Page 26: ...Description SIMOTICS HT Series HT direct 1FW4 1 A 26 Operating Instructions 11 2018 ...
Page 118: ...Service and Support SIMOTICS HT Series HT direct 1FW4 1 A 118 Operating Instructions 11 2018 ...
Page 122: ...Quality documents SIMOTICS HT Series HT direct 1FW4 1 A 122 Operating Instructions 11 2018 ...
Page 127: ......