Maintenance
9.2 Inspection and maintenance
Standard motors SH 63 ... 355
102
Operating Instructions, 12/2018, A5E38483075A
Measures, intervals and deadlines
Measures after operating period intervals or deadlines have elapsed:
Operating situations and characteristics can vary widely. For this reason, only general
maintenance intervals are specified here. Maintenance intervals should therefore be
scheduled to suit the local conditions (dirt, starting frequency, load, etc.).
Table 9- 3
Operating period intervals
Measures
Operating period intervals
Intervals
Initial inspection
After 500 operating hours
After 1/2 year at the latest
Relubrication (optional)
See the lubricant plate
Clean
Depending on the degree of pollution
Main inspection
Approximately every 16000 operating
hours
After two years at the latest
Drain condensate
Depending on the climatic conditions
9.2.7
Re-greasing
For machines with regreasing system, relubrication intervals, grease quantity and grease
grade are provided on the lubricant plate. Additional data can be taken from the main
machine rating plate.
Grade of grease for standard motors (IP55) UNIREX N3 - ESSO.
Note
It is not permissible to mix different types of grease.
Prolonged storage periods reduce the useful lifetime of the bearing grease. Check the
condition of the grease if the equipment has been in storage for more than 12 months. If the
grease is found to have lost oil content or to be contaminated, the machine must be
immediately relubricated before commissioning. For information on permanently-greased
bearings, please refer to the section titled Rolling bearings (Page 106).
Procedure
To relubricate the rolling bearings, proceed as follows:
1.
Clean the grease nipples at the drive end and non-drive end.
2.
Press-in the specified grease and amount of grease according to the data stamped on the
lubrication plate.
–
Please observe the information on the rating and lubricant plates.
–
Regreasing should be carried out when the motor is running (max. 3600 rpm).