![Siemens SIMOTICS DP series Operating Instructions Manual Download Page 37](http://html.mh-extra.com/html/siemens/simotics-dp-series/simotics-dp-series_operating-instructions-manual_379018037.webp)
Preparing for use
4.6 Ensure adequate cooling
Standard motors SH 63 ... 355
Operating Instructions, 12/2018, A5E38483075A
35
4.6
Ensure adequate cooling
WARNING
Overheating and failure of the motor
Death, severe injury or material damage can occur if you do not carefully observe the
following points.
•
Do not obstruct ventilation.
•
Prevent the air expelled by neighboring equipment from being immediately sucked in
again.
•
For machines with a vertical type construction with air entry from above, prevent the
ingress of foreign bodies and water in the air entry openings (standard IEC / EN 60079-
0).
•
If the shaft extension is facing upwards, liquid must be prevented from entering by
moving along the shaft.
WARNING
Damage caused by small parts falling in
Material damage and injury can occur if the fan is destroyed and therefore the motor
overheats.
•
For types of construction with the shaft extension facing downwards, prevent small parts
from falling into the fan cover by providing suitable covers (standard IEC / EN 60079-0).
•
Ensure that the cooling air flow is not reduced as a result of covers and that the
minimum air clearances are maintained.
For machines with external fans, install an interlock circuit that prevents the main machine
being switched on if the external fan is not operational.