3.3 Installation
Standard motors SH 63 ... 355
26
Operating Instructions, 12/2018, A5E38483075A
3.3.7
Optional built-on and built-in accessories
Machines can be equipped with the following integrated components/devices:
●
Temperature sensors integrated in the stator winding in order to monitor the temperature
and protect the stator winding from overheating.
●
Anti-condensation heating for machines whose windings are subject to a risk of
condensation due to the climatic conditions.
Machines can be equipped with the following mounted components/devices:
●
Brake
●
Rotary pulse encoder
●
External fan (forced ventilation)
●
Measuring nipple for SPM shock pulse measurement for bearing monitoring
●
Backstop
Note
Further documents
Observe all of the other documents provided with this machine.
Supplementary devices
Depending on the order, various supplementary devices can be installed or mounted. These
include sensors for bearing temperature monitoring or winding monitoring, for example.
3.3.8
Terminal box
As an option, additional connecting terminals are available in the terminal box for monitoring
equipment. For larger machines, an additional terminal box can be optionally mounted. You
can see the number of available terminals in the circuit diagrams.
3.3.9
Paint finish
Paint finish
The machine is painted according to the instructions in your order.